System description
The EM 712 multibeam echo sounder is a high to very high resolution seabed mapping
system.
The EM 712 multibeam echo sounder is capable of meeting all relevant survey standards.
The system configuration can be tailored to the user requirements, allowing for choice of
beamwidths as well as transmission modes. The minimum acquisition depth is from less
than 3 m below its transducers, and the maximum acquisition depth is up to 3600 m.
The EM 712 replaces the EM 710. EM 712 is built with new, state of the art technology.
By increasing the frequency range from 70-100 kHz to 40-100 kHz, the range
performance is greatly improved. The transmit transducer arrays are the same, while the
receive arrays has got a built in preamplifier. The preamplifier reduces the electronic self
noise and this gives extended range capability as long as the external noise (ships noise,
flow noise , sea-state) is low. The EM 712 receiver can be configured for 0.5°, using
two receiver modules. For upgrade from EM 710 to EM 712, the TX and RX frames
plus the transmit array(s) can be reused.
Acrosstrack coverage (swath width) is up to 5.5 times water depth and the maximum
achievable depth is 3600 m. The sounding density is very high, allowing even the very
demanding LINZ special order survey specification for object detection to be met in full.
There are three basic versions of the EM 712:
• EM 712 - Full performance version
• EM 712S (shallow) - Continuous wave (CW) pulse forms only
• EM 712RD (reduced depth) - Short CW pulse only, restricted to 600 m water depth.
The reduced performance versions EM 712S and EM 712RD can be upgraded to full
performance.
EM 712B, upgrade from EM 710
With EM 712B it is possible to upgrade EM 710 to EM 712 without replacing the
transducer modules.
To achieve this we have made a separate Receiver Unit scientifically tailored for
use with the EM 710 receive transducers. The EM 712B Receiver Unit has the same
measurements and weight as the regular Receiver Unit, but performs the preamplification
in the Receiver Unit instead of in the receive transducer.
Summary of Contents for EM 712
Page 8: ...8 451106 B Kongsberg EM 712 ...
Page 102: ...102 451106 B 216148 Transducer TX1 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 103: ...451106 B 103 Drawing file ...
Page 104: ...104 451106 B 221048 Transducer TX2 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 105: ...451106 B 105 Drawing file ...
Page 106: ...106 451106 B 219621 Transducer RX1 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 107: ...451106 B 107 Drawing file ...
Page 108: ...108 451106 B 216146 Transducer RX2 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 109: ...451106 B 109 Drawing file ...
Page 110: ...110 451106 B 223137 Transducer mounting frame 0 5 Kongsberg EM 712 Maintenance Manual ...
Page 111: ...451106 B 111 Drawing file ...
Page 112: ...112 451106 B 223139 Transducer mounting frame 1 Kongsberg EM 712 Maintenance Manual ...
Page 113: ...451106 B 113 Drawing file ...
Page 114: ...114 451106 B 223273 Transducer mounting frame 2 Kongsberg EM 712 Maintenance Manual ...
Page 115: ...451106 B 115 Drawing file ...
Page 116: ...116 451106 B 317812 Casing w mounting frame 0 5 Kongsberg EM 712 Maintenance Manual ...
Page 117: ...451106 B 117 320320 Casing w mounting frame 1 Drawing file ...
Page 118: ...118 451106 B 375817 Combined casing w mounting frame 1 Kongsberg EM 712 Maintenance Manual ...
Page 119: ...451106 B 119 331369 Casing w mounting frame 2 Drawing file ...
Page 120: ...120 451106 B 396402 EM 712 Transmitter Unit dimensions Kongsberg EM 712 Maintenance Manual ...
Page 121: ...451106 B 121 212984 EM 712 Transmitter Unit mounting bracket Drawing file ...
Page 122: ...122 451106 B 396428 EM 712 Receiver Unit dimensions Kongsberg EM 712 Maintenance Manual ...
Page 123: ...451106 B 123 385422 Processing Unit dimensions Drawing file ...
Page 124: ...124 451106 B 378828 Hydrographic Work Station dimensions Kongsberg EM 712 Maintenance Manual ...
Page 125: ...451106 B 125 Drawing file ...
Page 126: ...126 451106 B 371591 Rack installation kit dimenisons Kongsberg EM 712 Maintenance Manual ...
Page 127: ...451106 B 127 370275 Remote Control Unit K REM dimensions Drawing file ...
Page 128: ...128 451106 B Kongsberg EM 712 Maintenance Manual ...
Page 129: ...451106 B 129 373962 Remote Control Unit K REM wiring diagram Drawing file ...
Page 130: ...130 451106 B 409067 Fibre cable kit Kongsberg EM 712 Maintenance Manual ...
Page 144: ...144 451106 B Height 408 mm Weight 10 kg Approximately Kongsberg EM 712 Maintenance Manual ...
Page 219: ...451106 B 219 7 Observe the handling rules for transducers Equipment handling ...
Page 231: ......
Page 232: ... 2019 Kongsberg Maritime ...