152
451106/B
Read this first
Detailed information about cable specifications, termination and connectors is provided.
Unless otherwise specified, all cables are supplied by Kongsberg Maritime as a part
of the EM 712 delivery.
Detailed drawings are provided for relevant cables. Each drawing provides additional
information, and may, when applicable, include minimum specifications, connector
terminations and the required number of cores. Drawings are generally not provided for
standard commercial cables. Cables fall into three categories.
1
System cables
: These cables are provided by Kongsberg Maritime as a part of the
EM 712 delivery.
2
Shipyard cables
: These cables must be provided by the shipyard performing the
installation, or the shipowner. It is very important that the cables used meet the
minimum specifications provided in this manual.
3
Commercial cables
: These cables may be provided by Kongsberg Maritime as a part
of the EM 712 delivery. They may also be included with third party items that are
used with the EM 712.
All electronic installations and corresponding wiring must be in accordance with the
vessel's national registry and corresponding maritime authority and/or classification
society.
Note
It is very important that all cables are properly installed and correctly terminated.
Observe the relevant regulations and work standards. Always leave enough cable slack
close to system units and cabinets to allow for maintenance.
Only skilled and authorized personnel can install the EM 712 cables.
Kongsberg Maritime accepts no responsibility for damage to the system, or reduced
operational performance, when this is caused by improper wiring.
Before you install or maintain the EM 712 cables, make sure that the AC mains circuit
breaker for the system is switched off.
Kongsberg EM 712 Maintenance Manual
Summary of Contents for EM 712
Page 8: ...8 451106 B Kongsberg EM 712 ...
Page 102: ...102 451106 B 216148 Transducer TX1 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 103: ...451106 B 103 Drawing file ...
Page 104: ...104 451106 B 221048 Transducer TX2 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 105: ...451106 B 105 Drawing file ...
Page 106: ...106 451106 B 219621 Transducer RX1 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 107: ...451106 B 107 Drawing file ...
Page 108: ...108 451106 B 216146 Transducer RX2 dimensions Kongsberg EM 712 Maintenance Manual ...
Page 109: ...451106 B 109 Drawing file ...
Page 110: ...110 451106 B 223137 Transducer mounting frame 0 5 Kongsberg EM 712 Maintenance Manual ...
Page 111: ...451106 B 111 Drawing file ...
Page 112: ...112 451106 B 223139 Transducer mounting frame 1 Kongsberg EM 712 Maintenance Manual ...
Page 113: ...451106 B 113 Drawing file ...
Page 114: ...114 451106 B 223273 Transducer mounting frame 2 Kongsberg EM 712 Maintenance Manual ...
Page 115: ...451106 B 115 Drawing file ...
Page 116: ...116 451106 B 317812 Casing w mounting frame 0 5 Kongsberg EM 712 Maintenance Manual ...
Page 117: ...451106 B 117 320320 Casing w mounting frame 1 Drawing file ...
Page 118: ...118 451106 B 375817 Combined casing w mounting frame 1 Kongsberg EM 712 Maintenance Manual ...
Page 119: ...451106 B 119 331369 Casing w mounting frame 2 Drawing file ...
Page 120: ...120 451106 B 396402 EM 712 Transmitter Unit dimensions Kongsberg EM 712 Maintenance Manual ...
Page 121: ...451106 B 121 212984 EM 712 Transmitter Unit mounting bracket Drawing file ...
Page 122: ...122 451106 B 396428 EM 712 Receiver Unit dimensions Kongsberg EM 712 Maintenance Manual ...
Page 123: ...451106 B 123 385422 Processing Unit dimensions Drawing file ...
Page 124: ...124 451106 B 378828 Hydrographic Work Station dimensions Kongsberg EM 712 Maintenance Manual ...
Page 125: ...451106 B 125 Drawing file ...
Page 126: ...126 451106 B 371591 Rack installation kit dimenisons Kongsberg EM 712 Maintenance Manual ...
Page 127: ...451106 B 127 370275 Remote Control Unit K REM dimensions Drawing file ...
Page 128: ...128 451106 B Kongsberg EM 712 Maintenance Manual ...
Page 129: ...451106 B 129 373962 Remote Control Unit K REM wiring diagram Drawing file ...
Page 130: ...130 451106 B 409067 Fibre cable kit Kongsberg EM 712 Maintenance Manual ...
Page 144: ...144 451106 B Height 408 mm Weight 10 kg Approximately Kongsberg EM 712 Maintenance Manual ...
Page 219: ...451106 B 219 7 Observe the handling rules for transducers Equipment handling ...
Page 231: ......
Page 232: ... 2019 Kongsberg Maritime ...