Set Assumed Sound Velocity
where
xxxx
= '1400'…'1600' is the velocity in meters
per second.
'W'xx
–
Set Range Window
where
xx
= '01'..'99' is the range window size
calculated as a percentage of the
Maximum Range
setting. Entering a value of '00' disables the range
windowing feature.
'X'x
–
Select Transmit Power
where
x
is either '0' (low) or '1' (high).
'Y'xxxx
–
Set Minimum Ping Repetition Period
where
xxxx
is '0050'…'9999' milliseconds. The actual
repetition rate will be a function of many of the other
settings, but will be no less than the setting issued by
this command. This setting is particularly useful to
reduce the ping rate in conditions of significant
multipath.