1007D Altimeter Operators Manual
974-72007001/1.0
Telemetry Page
29
Kongsberg Mesotech Ltd.
Port Coquitlam, BC - Canada
'R'x
–
Set Operating Range
where
x
is one of:
'1'
0.75-20m
'2'
0.75-50m
'3'
0.75-100m
'4'
0.75-200m
'0'
Custom: range limits set by the Set
Custom Minimum Range and Set Custom
Maximum Range commands.
For all range settings, the altimeter attempts to
assume the best resolution possible limited by the
Set
Maximum Resolution
setting and hardware limits. The
actual resolution used can be determined by the '
-Q
'
QUERY command.
'S'x
–
Select NMEA Units
This command selects the units of the NMEA-format
range data, where
x
is one of:
'0'
meters
'1'
feet
'2'
fathoms