974-72007001/1.0 1007D
Altimeter Operators Manual
Page
16 Installation
Kongsberg Mesotech Ltd.
Port Coquitlam, BC - Canada
Figure 3.1 Typical 1007D Connection to MS1000 PC
3.3
System Checkout
After the system has been properly connected to a power
supply and to an external PC (or DC voltmeter for analog only
versions), it should be tested in 2 stages:
1.
With the unit OUT of the water, turn on the power supply,
and observe the following:
over-range output (time = 0.0usec or empty range
field) received by the external PC. For analog output,
the over-range output level +/- 0.05V should be
measured by the DC voltmeter.
If possible, confirm that supply current is between 150
and 450 milliamps.
2.
If all of the above appears normal, the system should be
tested in water of known depth within the unit's minimum
PC laptop with MS1000
1071 head cable
serial cable
to serial
port
MS1000
Power Supply
Sonar Head
PC / RS-232
Telemetry Extension
1007D Altimeter