1007D Altimeter Operators Manual
974-72007001/1.0
Telemetry Page
19
Kongsberg Mesotech Ltd.
Port Coquitlam, BC - Canada
b)
Issue the desired command string to the altimeter, then
wait for and process acknowledgment from the
altimeter (if any).
c)
Issue XON (Ctrl-Q) character to the altimeter to
resume pinging and data up-link.
The serial communications settings for digital
communications in all modes and protocols are 8
bits/character, 1 start bit, 1 stop bit, and no parity. A standard
default baud rate of 9600 bits/second is programmed at the
factory. Consult the factory if a different default rate is
required.
4.1
808 Mode Messages
This section outlines the uplink and downlink messages
recognized in 808 mode.
4.1.1
Uplink Messages
Range data is output from the altimeter after every ping, in the
following ASCII format:
+
ddddd
CRLF