ATTACHMENTS, OPTIONS
MINING SPECIFICATION MACHINE
CARRYING OUT KOWA (Komatsu Oil Wear Analysis)
OIL SAMPLING
Sampling interval
500 hours
Precautions when sampling
Make sure that the oil is well mixed before sampling.
Perform sampling at regular fixed intervals.
Do not perform sampling on rainy or windy days when water or dust can get into the oil.
If an oil sampling coupler is equipped, use the coupler to sample the oil. (if equipped.)
(1): Coolant
(2): Engine oil
(3): Hydraulic oil
(4): Power train oil
Test port
Part No.799-101-5220
Mounting screw
Size: M10 x 1.25 (SAE O-ring boss)
Precautions when sampling
Run the engine at low idling when sampling.
Park the machine before carrying out sampling.
(Parking brake ON, work equipment lock lever ON, steering lock lever ON)
The sampled oil is at high temperature, so be careful not to burn yourself.
Oil inside the hose contains remained oil from last sampling. If you start sampling as it is, it may cause the error.
When sampling, do not collect the oil into the bottle as it is, pour some amount of oil into another bottle, and then
collect the oil into the bottle.
Immediately after the engine is started, the wear powder precipitates in the oil and the oil density may be low so
that the signs of error may not be found. Start the engine before collecting the oil.
For further details of KOWA, contact your Komatsu distributor.
6 - 43
Summary of Contents for D475A-5E0
Page 2: ... 1 1 ...
Page 14: ... 2 1 ...
Page 53: ... ...
Page 54: ... 3 1 ...
Page 243: ... ...
Page 244: ... 4 1 ...
Page 301: ... MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE A Right of machine 4 58 ...
Page 338: ... 5 1 ...
Page 340: ... 6 1 ...
Page 401: ... ...