![Komatsu 75001 Shop Manual Download Page 945](http://html.mh-extra.com/html/komatsu/75001/75001_shop-manual_1991114945.webp)
SEN03848-00
40-400
68
WA250, 250PZ-6
400 Troubleshooting of electrical system (E-mode)
E-16 Alarm buzzer does not sound or it keeps sounding
E-16 Alarm buzzer does not sound or it keeps sounding
1
Contents of
trouble
• Alarm buzzer does not sound or it keeps sounding.
Related
information
• Disconnection or ground fault in alarm buzzer output circuit
• The output state (ON/OFF) from the alarm buzzer to the machine monitor can be checked with the
monitoring function (Code: MONITOR PANEL 40952, D-OUT-0).
• If failure code is indicated, carry out troubleshooting for it first.
Possible
causes and
standard value
in normal state
Causes
Standard value in normal state/Remarks on troubleshooting
1
Defective fuse No.6 of fuse
box 1
If the fuse is burn, the circuit probably has a grounding fault, etc.
(See cause 4.)
2
Defective alarm buzzer
(Internal trouble)
a
Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
• Remove the buzzer then c24 V to L46 (male) (1) and
GND to L46 (male) (2).
Alarm buzzer sounds
Alarm buzzer is
normal
Alarm buzzer does not sound
Defective alarm
buzzer
3
Disconnection in wiring har-
ness
(Disconnection or defective
contact in connector)
a
Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between fuse No. 6 of fuse
box FS1 – L46 (female) (1)
Resis-
tance
Max. 1
z
Wiring harness between L46 (female) (2) –
L24 (female) (14)
Resis-
tance
Max. 1
z
4
Ground fault in wiring harness
(Contact with ground circuit)
a
Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between fuse No. 6 of fuse
box 1 – L46 (female) (1), – circuit branch end
and ground
Resis-
tance
Min.
1 M
z
Wiring harness between L46 (female) (2) –
L24 (female) (14) and ground
Resis-
tance
Min.
1 M
z
5 Defective machine monitor
• When above 1 – 4 are normal, failure on the machine monitor can
be suspected.
Summary of Contents for 75001
Page 1: ...WHEEL LOADER SEN03813 03 WA250 6 WA250PZ 6 SERIAL NUMBERS WA250 75001 WA250PZ 75001 and up ...
Page 14: ...SEN03822 03 WA250 250PZ 6 00 100 13 Table of contents 100 Index ...
Page 56: ...SEN03823 01 WA250 250PX 6 00 200 41 200 Foreword and general information Conversion table ...
Page 59: ...SEN03824 00 01 100 2 WA250 250PZ 6 100 Specification and technical data ...
Page 77: ...SEN03825 00 10 100 8 WA250 250PZ 6 100 Engine and cooling system Cooling fan motor ...
Page 84: ...SEN03825 00 WA250 250PZ 6 10 100 15 100 Engine and cooling system Cooling fan motor ...
Page 87: ...SEN03826 00 10 200 2 WA250 250PZ 6 200 Power train ...
Page 111: ...SEN03826 00 10 200 26 WA250 250PZ 6 200 Power train Transfer Output shaft ...
Page 113: ...SEN03826 00 10 200 28 WA250 250PZ 6 200 Power train Transfer ...
Page 128: ...SEN03826 00 WA250 250PZ 6 10 200 43 200 Power train Torque proportioning differential ...
Page 138: ...SEN03826 00 WA250 250PZ 6 10 200 53 200 Power train Final drive ...
Page 141: ...SEN03827 01 10 300 2 WA250 250PZ 6 300 Steering system ...
Page 164: ...SEN03827 01 WA250 250PZ 6 10 300 25 300 Steering system Steering relief valve ...
Page 167: ...SEN03828 00 10 400 2 WA250 250PZ 6 400 Brake system ...
Page 169: ...SEN03828 00 10 400 4 WA250 250PZ 6 400 Brake system Charge valve Charge valve 1 ...
Page 188: ...SEN03828 00 WA250 250PZ 6 10 400 23 400 Brake system Parking brake ...
Page 213: ...SEN03830 00 10 600 16 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 217: ...SEN03830 00 10 600 20 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 221: ...SEN03830 00 10 600 24 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 225: ...SEN03830 00 10 600 28 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 248: ...SEN03830 00 WA250 250PZ 6 10 600 51 600 Hydraulic system PPC valve ...
Page 260: ...SEN03830 00 WA250 250PZ 6 10 600 63 600 Hydraulic system Accumulator for ECSS ...
Page 265: ...SEN03831 00 10 700 4 WA250 250PZ 6 700 Work equipment Work equipment linkage WA250PZ 6 ...
Page 283: ...SEN03831 00 10 700 22 WA250 250PZ 6 700 Work equipment Bucket positioner and boom kick out ...
Page 289: ...SEN03832 00 10 800 2 WA250 250PZ 6 800 Cab and its attachments ...
Page 300: ...SEN03832 00 WA250 250PZ 6 10 800 13 800 Cab and its attachments Air conditioner ...
Page 308: ...SEN03833 01 WA250 250PZ 6 10 910 5 910 Electrical system Part 1 Machine monitor system ...
Page 330: ...SEN03833 01 WA250 250PZ 6 10 910 27 910 Electrical system Part 1 Machine monitor ...
Page 350: ...SEN03834 01 WA250 250PZ 6 10 920 19 920 Electrical system Part 2 HST controller ...
Page 372: ...SEN03834 01 WA250 250PZ 6 10 920 41 920 Electrical system Part 2 Sensor ...
Page 386: ...SEN03836 01 30 110 3 WA250 250PZ 6 110 Testing and adjusting Part 1 ...
Page 546: ...SEN03839 00 WA250 250PZ 6 40 100 11 100 Failure code table and fuse locations Fuse locations ...
Page 674: ...SEN03843 00 WA250 250PZ 6 40 330 3 330 Troubleshooting by failure code Display of code Part 3 ...
Page 773: ...SEN03845 00 40 350 2 WA250 250PZ 6 350 Troubleshooting by failure code Display of code Part 5 ...
Page 813: ...SEN03846 00 40 360 2 WA250 250PZ 6 360 Troubleshooting by failure code Display of code Part 6 ...
Page 879: ...SEN03848 00 40 400 2 WA250 250PZ 6 400 Troubleshooting of electrical system E mode ...
Page 1275: ...SEN03860 01 90 100 2 WA250 250PZ 6 100 Hydraulic diagrams and drawings ...
Page 1278: ...SEN03860 01 WA250 250PZ 6 90 100 7 100 Hydraulic diagrams and drawings ...
Page 1281: ...SEN03861 01 90 200 2 WA250 250PZ 6 200 Electrical diagrams and drawings ...
Page 1292: ...SEN03861 01 WA250 250PZ 6 90 200 23 200 Electrical diagrams and drawings ...