SEN03835-00
20-100
4
WA250, 250PZ-6
100 Standard service value table
Standard service value table for chassis
S
te
er
ing
w
h
ee
l
Play
• Engine stopped
• Machine facing straight to front
mm
20 ± 20
Max. 60
Operating effort
• Flat, level, straight, dry, and paved road
• Engine speed: Low idle (Bucket empty)
N {kg}
9.8 ± 2.9
{1.0 ± 0.3}
Max.14.7
{Max. 1.5}
Turns (Not including play)
• Engine speed: High idle
• Left lock – right lock
Turns
3.7 ± 0.4
3.7 ± 0.8
Operating time
Low idle
• Engine started
• Hydraulic oil temperature: Within operat-
ing range
• Left lock – right lock
sec.
3.7 ± 0.4
Max. 4.8
High idle
3.7 ± 0.3
3.7 ± 1
Ac
ce
le
ra
to
r p
e
d
a
l
Operating effort
Beginning of
depression
• Engine started
• Measure at 150 mm from fulcrum of
pedal.
N {kg}
24.5 – 37.8
{2.5 – 3.9}
—
Full open
45.5 – 58.8
{4.6 – 6.0}
—
Operating
angle
Neutral (
α
1)
a
For measuring posture, see Fig. A at end
of this section
• Engine started
•
α = α
1–
α
2
deg.
45 ± 2
—
stroke (
α
)
17 ± 2
—
B
rak
e pe
da
l
Operating effort
• Operating angle: 20°
• Engine speed: Low idle
• Hydraulic oil temperature: Within operat-
ing range
N {kg}
294 ± 30
{30 ± 3.0}
Min. 238
{Min. 24.3}
Operating
angle
Neutral (
α
1)
a
For measuring posture, see Fig. B at end
of this section
• Engine speed: Low idle
• Hydraulic oil temperature: Within operat-
ing range
deg.
50
—
Max. (
α
2)
20 (+2/0)
—
Play
5 ± 1
—
E
n
gi
ne
s
pe
ed
HST stall
• Engine coolant temperature: Within oper-
ating range
• HST oil temperature: 60 – 80°C
• Hydraulic oil temperature: 45 – 55°C
rpm
2,180 ± 100
2,180 (+115/–200)
Hydraulic stall
2,070 ± 100
2,070 ± 200
HST stall + hydraulic stall
2,040 (+130/–200) 2,040 (+230/–300)
P
ow
e
r t
rai
n (
H
S
T
)
Travel speed
(Bucket empty)
FORWARD
1st
km/h
4 ± 0.2
4 ± 0.3
2nd
13 ± 0.7
13 ± 0.9
3rd
18 ± 0.9
18 ± 1.3
4th
38 ± 1.9
38 (+1.9/–2.7)
Machine model
WA250-6
Ca
te
g
o
ry
Item
Measurement conditions
Unit
Standard value for
new machine
Service limit value
Summary of Contents for 75001
Page 1: ...WHEEL LOADER SEN03813 03 WA250 6 WA250PZ 6 SERIAL NUMBERS WA250 75001 WA250PZ 75001 and up ...
Page 14: ...SEN03822 03 WA250 250PZ 6 00 100 13 Table of contents 100 Index ...
Page 56: ...SEN03823 01 WA250 250PX 6 00 200 41 200 Foreword and general information Conversion table ...
Page 59: ...SEN03824 00 01 100 2 WA250 250PZ 6 100 Specification and technical data ...
Page 77: ...SEN03825 00 10 100 8 WA250 250PZ 6 100 Engine and cooling system Cooling fan motor ...
Page 84: ...SEN03825 00 WA250 250PZ 6 10 100 15 100 Engine and cooling system Cooling fan motor ...
Page 87: ...SEN03826 00 10 200 2 WA250 250PZ 6 200 Power train ...
Page 111: ...SEN03826 00 10 200 26 WA250 250PZ 6 200 Power train Transfer Output shaft ...
Page 113: ...SEN03826 00 10 200 28 WA250 250PZ 6 200 Power train Transfer ...
Page 128: ...SEN03826 00 WA250 250PZ 6 10 200 43 200 Power train Torque proportioning differential ...
Page 138: ...SEN03826 00 WA250 250PZ 6 10 200 53 200 Power train Final drive ...
Page 141: ...SEN03827 01 10 300 2 WA250 250PZ 6 300 Steering system ...
Page 164: ...SEN03827 01 WA250 250PZ 6 10 300 25 300 Steering system Steering relief valve ...
Page 167: ...SEN03828 00 10 400 2 WA250 250PZ 6 400 Brake system ...
Page 169: ...SEN03828 00 10 400 4 WA250 250PZ 6 400 Brake system Charge valve Charge valve 1 ...
Page 188: ...SEN03828 00 WA250 250PZ 6 10 400 23 400 Brake system Parking brake ...
Page 213: ...SEN03830 00 10 600 16 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 217: ...SEN03830 00 10 600 20 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 221: ...SEN03830 00 10 600 24 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 225: ...SEN03830 00 10 600 28 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 248: ...SEN03830 00 WA250 250PZ 6 10 600 51 600 Hydraulic system PPC valve ...
Page 260: ...SEN03830 00 WA250 250PZ 6 10 600 63 600 Hydraulic system Accumulator for ECSS ...
Page 265: ...SEN03831 00 10 700 4 WA250 250PZ 6 700 Work equipment Work equipment linkage WA250PZ 6 ...
Page 283: ...SEN03831 00 10 700 22 WA250 250PZ 6 700 Work equipment Bucket positioner and boom kick out ...
Page 289: ...SEN03832 00 10 800 2 WA250 250PZ 6 800 Cab and its attachments ...
Page 300: ...SEN03832 00 WA250 250PZ 6 10 800 13 800 Cab and its attachments Air conditioner ...
Page 308: ...SEN03833 01 WA250 250PZ 6 10 910 5 910 Electrical system Part 1 Machine monitor system ...
Page 330: ...SEN03833 01 WA250 250PZ 6 10 910 27 910 Electrical system Part 1 Machine monitor ...
Page 350: ...SEN03834 01 WA250 250PZ 6 10 920 19 920 Electrical system Part 2 HST controller ...
Page 372: ...SEN03834 01 WA250 250PZ 6 10 920 41 920 Electrical system Part 2 Sensor ...
Page 386: ...SEN03836 01 30 110 3 WA250 250PZ 6 110 Testing and adjusting Part 1 ...
Page 546: ...SEN03839 00 WA250 250PZ 6 40 100 11 100 Failure code table and fuse locations Fuse locations ...
Page 674: ...SEN03843 00 WA250 250PZ 6 40 330 3 330 Troubleshooting by failure code Display of code Part 3 ...
Page 773: ...SEN03845 00 40 350 2 WA250 250PZ 6 350 Troubleshooting by failure code Display of code Part 5 ...
Page 813: ...SEN03846 00 40 360 2 WA250 250PZ 6 360 Troubleshooting by failure code Display of code Part 6 ...
Page 879: ...SEN03848 00 40 400 2 WA250 250PZ 6 400 Troubleshooting of electrical system E mode ...
Page 1275: ...SEN03860 01 90 100 2 WA250 250PZ 6 100 Hydraulic diagrams and drawings ...
Page 1278: ...SEN03860 01 WA250 250PZ 6 90 100 7 100 Hydraulic diagrams and drawings ...
Page 1281: ...SEN03861 01 90 200 2 WA250 250PZ 6 200 Electrical diagrams and drawings ...
Page 1292: ...SEN03861 01 WA250 250PZ 6 90 200 23 200 Electrical diagrams and drawings ...