SEN03845-00
40-350
22
WA250, 250PZ-6
350 Troubleshooting by failure code (Display of code), Part 5
Failure code [DDD7KX] Travel speed control dial signal: Disconnection/Ground fault
Failure code [DDD7KX] Travel speed control dial signal: Disconnection/
Ground fault
Action code
Failure code
Trouble
Travel speed control dial signal: Disconnection/Ground fault
(HST controller system)
E01
DDD7KX
Contents of
trouble
• Travel speed control dial signal voltage lowered below 0.3 V.
Action of
controller
• Continue controls on assumption that travel speed control dial is set to minimum speed side.
• Even if trouble disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
machine
• Travel speed cannot be adjusted with travel speed control dial.
• If speed range selector switch is set in 1st, travel speed is set to about 4 km/h.
Related
information
• If failure code [DAJ5KX] is also displayed, carry out troubleshooting for it first.
Possible causes
and standard
value in normal
state
Causes
Standard value in normal state/Remarks on troubleshooting
1
Defective travel speed con-
trol dial (Internal defect)
a
Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Between L54 (female) (A) – (C)
Voltage
4.7 – 5.3
V
Between L54 (female) (B) – (C) (Max. speed
side of dial)
Voltage
0.3 – 0.9
V
Between L54 (female) (B) – (C) (Min. speed
side of dial)
Voltage
4.1 – 4.7
V
2
Disconnection in wiring har-
ness (Disconnection in wiring
or defective contact in con-
nector)
a
Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between HST (female) (23) –
L54 (female) (B)
Resis-
tance
Max. 1
z
Wiring harness between HST (female) (22) –
L54 (female) (A)
Resis-
tance
Max. 1
z
3
Ground fault in wiring har-
ness (Contact with GND cir-
cuit)
a
Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Between wiring harness HST (female) (23) –
L54 (female) and ground
Resis-
tance
Min.
1 M
z
4
Defective HST controller
a
Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
HST (female)
Resistance
Between (32) – ground
Max. 1
z
a
Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
HST (female)
Voltage
Between (22) – ground
4.7 – 5.3 V
Between (23) – ground
0.3 – 4.7 V
Summary of Contents for 75001
Page 1: ...WHEEL LOADER SEN03813 03 WA250 6 WA250PZ 6 SERIAL NUMBERS WA250 75001 WA250PZ 75001 and up ...
Page 14: ...SEN03822 03 WA250 250PZ 6 00 100 13 Table of contents 100 Index ...
Page 56: ...SEN03823 01 WA250 250PX 6 00 200 41 200 Foreword and general information Conversion table ...
Page 59: ...SEN03824 00 01 100 2 WA250 250PZ 6 100 Specification and technical data ...
Page 77: ...SEN03825 00 10 100 8 WA250 250PZ 6 100 Engine and cooling system Cooling fan motor ...
Page 84: ...SEN03825 00 WA250 250PZ 6 10 100 15 100 Engine and cooling system Cooling fan motor ...
Page 87: ...SEN03826 00 10 200 2 WA250 250PZ 6 200 Power train ...
Page 111: ...SEN03826 00 10 200 26 WA250 250PZ 6 200 Power train Transfer Output shaft ...
Page 113: ...SEN03826 00 10 200 28 WA250 250PZ 6 200 Power train Transfer ...
Page 128: ...SEN03826 00 WA250 250PZ 6 10 200 43 200 Power train Torque proportioning differential ...
Page 138: ...SEN03826 00 WA250 250PZ 6 10 200 53 200 Power train Final drive ...
Page 141: ...SEN03827 01 10 300 2 WA250 250PZ 6 300 Steering system ...
Page 164: ...SEN03827 01 WA250 250PZ 6 10 300 25 300 Steering system Steering relief valve ...
Page 167: ...SEN03828 00 10 400 2 WA250 250PZ 6 400 Brake system ...
Page 169: ...SEN03828 00 10 400 4 WA250 250PZ 6 400 Brake system Charge valve Charge valve 1 ...
Page 188: ...SEN03828 00 WA250 250PZ 6 10 400 23 400 Brake system Parking brake ...
Page 213: ...SEN03830 00 10 600 16 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 217: ...SEN03830 00 10 600 20 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 221: ...SEN03830 00 10 600 24 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 225: ...SEN03830 00 10 600 28 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 248: ...SEN03830 00 WA250 250PZ 6 10 600 51 600 Hydraulic system PPC valve ...
Page 260: ...SEN03830 00 WA250 250PZ 6 10 600 63 600 Hydraulic system Accumulator for ECSS ...
Page 265: ...SEN03831 00 10 700 4 WA250 250PZ 6 700 Work equipment Work equipment linkage WA250PZ 6 ...
Page 283: ...SEN03831 00 10 700 22 WA250 250PZ 6 700 Work equipment Bucket positioner and boom kick out ...
Page 289: ...SEN03832 00 10 800 2 WA250 250PZ 6 800 Cab and its attachments ...
Page 300: ...SEN03832 00 WA250 250PZ 6 10 800 13 800 Cab and its attachments Air conditioner ...
Page 308: ...SEN03833 01 WA250 250PZ 6 10 910 5 910 Electrical system Part 1 Machine monitor system ...
Page 330: ...SEN03833 01 WA250 250PZ 6 10 910 27 910 Electrical system Part 1 Machine monitor ...
Page 350: ...SEN03834 01 WA250 250PZ 6 10 920 19 920 Electrical system Part 2 HST controller ...
Page 372: ...SEN03834 01 WA250 250PZ 6 10 920 41 920 Electrical system Part 2 Sensor ...
Page 386: ...SEN03836 01 30 110 3 WA250 250PZ 6 110 Testing and adjusting Part 1 ...
Page 546: ...SEN03839 00 WA250 250PZ 6 40 100 11 100 Failure code table and fuse locations Fuse locations ...
Page 674: ...SEN03843 00 WA250 250PZ 6 40 330 3 330 Troubleshooting by failure code Display of code Part 3 ...
Page 773: ...SEN03845 00 40 350 2 WA250 250PZ 6 350 Troubleshooting by failure code Display of code Part 5 ...
Page 813: ...SEN03846 00 40 360 2 WA250 250PZ 6 360 Troubleshooting by failure code Display of code Part 6 ...
Page 879: ...SEN03848 00 40 400 2 WA250 250PZ 6 400 Troubleshooting of electrical system E mode ...
Page 1275: ...SEN03860 01 90 100 2 WA250 250PZ 6 100 Hydraulic diagrams and drawings ...
Page 1278: ...SEN03860 01 WA250 250PZ 6 90 100 7 100 Hydraulic diagrams and drawings ...
Page 1281: ...SEN03861 01 90 200 2 WA250 250PZ 6 200 Electrical diagrams and drawings ...
Page 1292: ...SEN03861 01 WA250 250PZ 6 90 200 23 200 Electrical diagrams and drawings ...