![Komatsu 75001 Shop Manual Download Page 755](http://html.mh-extra.com/html/komatsu/75001/75001_shop-manual_1991114755.webp)
SEN03844-00
40-340
28
WA250, 250PZ-6
340 Troubleshooting by failure code (Display of code), Part 4
Failure code [DAJ2KK] Controller solenoid power supply: Low voltage
Failure code [DAJ2KK] Controller solenoid power supply: Low voltage
Action code
Failure code
Trouble
Controller solenoid power supply: Low voltage
(HST controller system)
E03
DAJ2KK
Contents of
trouble
• Low voltage was detected in controller solenoid power supply system.
(While VIS power supply self-holding relay is ON and battery voltage is above 20 V, solenoid power
supply voltage below 18 V was detected.)
Action of
machine monitor
• Turns all outputs OFF.
Problem that
appears on
machine
• Machine cannot travel.
• Another failure may not be detected.
Related
information
• If gear is set in neutral and engine is restarted while solenoid voltage is above 19 V, system is reset.
Possible causes
and standard
value in normal
state
Causes
Standard value in normal state/Remarks on troubleshooting
1
Defective VIS power supply
holding relay (Internal defect)
a
Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Replace VIS power
supply holding relay
(L102) with another
relay.
Condition becomes
normal.
Relay (L102) is
defective.
Condition does not
become normal.
Relay (L102) is
normal.
a
Prepare with starting switch OFF, then check unit.
Between terminals of
L102 (male) (3) – (5)
When 24 V is applied
between (1) – (2)
Resis-
tance
Max. 1
z
When no voltage is
applied between (1) –
(2)
Resis-
tance
Min. 1 M
z
2
Disconnection in wiring har-
ness (Disconnection in wiring
or defective contact in con-
nector)
a
Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between HST (female) (30) –
L102 (female) (3)
Resis-
tance
Max. 1
z
3
Defective HST controller
a
Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Wiring harness between L102 (female) (5) –
fuse FS1 (No. 3)
Resis-
tance
Max. 1
z
HST
Voltage
Between (30) – ground
20 – 30 V
Summary of Contents for 75001
Page 1: ...WHEEL LOADER SEN03813 03 WA250 6 WA250PZ 6 SERIAL NUMBERS WA250 75001 WA250PZ 75001 and up ...
Page 14: ...SEN03822 03 WA250 250PZ 6 00 100 13 Table of contents 100 Index ...
Page 56: ...SEN03823 01 WA250 250PX 6 00 200 41 200 Foreword and general information Conversion table ...
Page 59: ...SEN03824 00 01 100 2 WA250 250PZ 6 100 Specification and technical data ...
Page 77: ...SEN03825 00 10 100 8 WA250 250PZ 6 100 Engine and cooling system Cooling fan motor ...
Page 84: ...SEN03825 00 WA250 250PZ 6 10 100 15 100 Engine and cooling system Cooling fan motor ...
Page 87: ...SEN03826 00 10 200 2 WA250 250PZ 6 200 Power train ...
Page 111: ...SEN03826 00 10 200 26 WA250 250PZ 6 200 Power train Transfer Output shaft ...
Page 113: ...SEN03826 00 10 200 28 WA250 250PZ 6 200 Power train Transfer ...
Page 128: ...SEN03826 00 WA250 250PZ 6 10 200 43 200 Power train Torque proportioning differential ...
Page 138: ...SEN03826 00 WA250 250PZ 6 10 200 53 200 Power train Final drive ...
Page 141: ...SEN03827 01 10 300 2 WA250 250PZ 6 300 Steering system ...
Page 164: ...SEN03827 01 WA250 250PZ 6 10 300 25 300 Steering system Steering relief valve ...
Page 167: ...SEN03828 00 10 400 2 WA250 250PZ 6 400 Brake system ...
Page 169: ...SEN03828 00 10 400 4 WA250 250PZ 6 400 Brake system Charge valve Charge valve 1 ...
Page 188: ...SEN03828 00 WA250 250PZ 6 10 400 23 400 Brake system Parking brake ...
Page 213: ...SEN03830 00 10 600 16 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 217: ...SEN03830 00 10 600 20 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 221: ...SEN03830 00 10 600 24 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 225: ...SEN03830 00 10 600 28 WA250 250PZ 6 600 Hydraulic system Work equipment control valve ...
Page 248: ...SEN03830 00 WA250 250PZ 6 10 600 51 600 Hydraulic system PPC valve ...
Page 260: ...SEN03830 00 WA250 250PZ 6 10 600 63 600 Hydraulic system Accumulator for ECSS ...
Page 265: ...SEN03831 00 10 700 4 WA250 250PZ 6 700 Work equipment Work equipment linkage WA250PZ 6 ...
Page 283: ...SEN03831 00 10 700 22 WA250 250PZ 6 700 Work equipment Bucket positioner and boom kick out ...
Page 289: ...SEN03832 00 10 800 2 WA250 250PZ 6 800 Cab and its attachments ...
Page 300: ...SEN03832 00 WA250 250PZ 6 10 800 13 800 Cab and its attachments Air conditioner ...
Page 308: ...SEN03833 01 WA250 250PZ 6 10 910 5 910 Electrical system Part 1 Machine monitor system ...
Page 330: ...SEN03833 01 WA250 250PZ 6 10 910 27 910 Electrical system Part 1 Machine monitor ...
Page 350: ...SEN03834 01 WA250 250PZ 6 10 920 19 920 Electrical system Part 2 HST controller ...
Page 372: ...SEN03834 01 WA250 250PZ 6 10 920 41 920 Electrical system Part 2 Sensor ...
Page 386: ...SEN03836 01 30 110 3 WA250 250PZ 6 110 Testing and adjusting Part 1 ...
Page 546: ...SEN03839 00 WA250 250PZ 6 40 100 11 100 Failure code table and fuse locations Fuse locations ...
Page 674: ...SEN03843 00 WA250 250PZ 6 40 330 3 330 Troubleshooting by failure code Display of code Part 3 ...
Page 773: ...SEN03845 00 40 350 2 WA250 250PZ 6 350 Troubleshooting by failure code Display of code Part 5 ...
Page 813: ...SEN03846 00 40 360 2 WA250 250PZ 6 360 Troubleshooting by failure code Display of code Part 6 ...
Page 879: ...SEN03848 00 40 400 2 WA250 250PZ 6 400 Troubleshooting of electrical system E mode ...
Page 1275: ...SEN03860 01 90 100 2 WA250 250PZ 6 100 Hydraulic diagrams and drawings ...
Page 1278: ...SEN03860 01 WA250 250PZ 6 90 100 7 100 Hydraulic diagrams and drawings ...
Page 1281: ...SEN03861 01 90 200 2 WA250 250PZ 6 200 Electrical diagrams and drawings ...
Page 1292: ...SEN03861 01 WA250 250PZ 6 90 200 23 200 Electrical diagrams and drawings ...