M-SS-017-07 Rev C
16
SERVO
STAR
CD
BUS M
ODULE
E
LECTRICAL
S
PECIFICATIONS
NOTE
NOT USED FOR SERIES 5.
Product Model
PA-LM
Logic Input Power
Voltage (AC) Nom.
?
10%
110 to 120
Max. Current 1
?
(A)
1
Line Frequency
47-63
Internal Fuse (amps) (internal)
2.5
+8 VDC Supply Voltage (VDC)
+7.25 to +8.5
+8 VDC Supply Current (amps)
2.2
15 V Supply Voltage (±VDC)
14.25 to 16
15 V Supply Current (amps)
0.8
Internal Fuses (amps) (
?
15V/+8 V)
1.5/3.5
Logic Output
Power (Source)
Max. # of Drives Sourced
Refer to Bus Module Sizing Application Note
Internal heat dissipation
7
Operation temperature (
?
C/
?
F)
5/41 to 45/113
Storage temperature (
?
C/
?
F)
0/32 to 70/158
Ambient humidity (%)
10 to 90
Atmosphere
without corrosive gasses or dust
Altitude
Derate 5% per 1000 ft. above 3300 ft.
Environment
Vibration (g)
0.5
R
EGEN
I
NFORMATION
Product Model
Cx03
Cx06
Cx10
Peak current (amps)
20
Minimum resistance (ohms)
20
External Shunt Regulator
watts
200
Capacitance (Farads)
0.00082
0.00164
BUS Voltage (nominal) (VDC)
325
V
HYS
(Regen circuit turn-off) (VDC)
370
Application Information
V
MAX
(Regen circuit turn-on) (VDC)
390
External Regen Kits
ERH-26
?
?
?
*See the SERVO
STAR
®
S/CD-Series Regeneration Requirements Application Note on the PSP CD-
ROM for guidance on application sizing of Regen Kits.
StockCheck.com