66
6-3. Input/Output Signal Interface
Motor connection terminal “PM1/PM2”
Emergency stop signal input terminal “EMG_IN”
Emergency stop signal output terminal “EMG_OUT”
*GND of CW-LS, CCWLS, NORG,
ORG is 0V(24)
24V
24V_OUT
EMG-IN
5kΩ
0V(24)
Current IC: 30[mA]
Rated voltage VECO: 80[V]
Rated voltage VECO: 5[V]
Photo-coupler permissible value
12V
CW-LS,CCWLS,
NORG,ORG
4.7kΩ
0V(24)
24V
+24V(24)
0V
EMG-OUT