9
Filter Blanking
cap
Filter cap
‘o’ Seal
Filter
Inlet Filters
Important!
the Inlet Filters should be checked and cleaned as necessary every
months.
note!
the Inlet Filters must not be removed except for cleaning. If the thermostatic
Mixer is operated without the Inlet Filters fitted the Warranty on the product will be
void.
1.
Isolate the hot and cold water supplies and operate the control Knob to drain
any residual water.
2.
remove the Filter Blanking caps and unscrew the Filter caps with the ‘o Key’
(supplied) or a mm hexagonal wrench and remove the Filters.
3.
clean each Filter in turn under a jet of water to remove any lodged particles.
4.
Refit the Filters and tighten the Filter Caps.
note!
Make sure that the seal is fitted correctly and not damaged.
5.
Refit the Filter Blanking Caps.
6.
turn on the hot and cold water supplies and check for leaks.