ReVeRseD InLeT suPPLIes
the Kohler Salute thermostatic mixer is supplied with inlet connections hot-left,
cold-right and Bottom-outlet as standard. If the hot and cold water supply pipes have
been reversed during installation the following procedure must be performed.
1.
Isolate the hot and cold water supplies.
2.
remove the Blanking cap, loosen the Grubscrew and pull off the control
Knob.
3.
Pull off the Bearing.
4.
Fit the ‘o’ Key (supplied) onto the cartridge Nut and turn anticlockwise. unscrew
fully and pull the cartridge from the Body.
5.
rotate the cartridge 80°.
6.
Make sure that the two Cartridge Inlet Seals are fitted and carefully push into
the Body, aligning the cartridge lugs into the Body Slots.
note!
make sure that the cartridge lug stamped ‘h’ is aligned with the hot inlet
supply.
Important!
Take care when fitting the Cartridge as damage to the Cartridge
Inlet Seals may result in dripping from the Shower head.
7.
tighten the Nut by turning the ‘o’ Key clockwise.
8.
Refit the Bearing.
9.
Refit the Control Knob, tighten the Grubscrew and refit the Blanking Cap.
10.
turn on the hot and cold water supplies and check for leaks.
11.
the maximum temperature of the thermostatic mixer is factory set to approximately
43°c. If adjustment is required, refer to section:
‘Commissioning’
.
Bearing
control Knob
Grubscrew
Blanking cap
‘o’ Key