0
1.1
use the Installation template to mark
the positions of the holes for the
Backplate and the pipe centres.
note!
allow a minimum of 50 mm
either side of the thermostatic mixer,
to allow access to the hot and cold
Inlet Filters for servicing.
1.2
For solid walls drill the Backplate
holes with a 6 mm diameter drill
and insert the Wall Plugs (supplied).
For other types of wall structure
alternative fixing may be required (not
supplied).
1.3
Drill the supply pipe holes at 53 mm
centres.
1.4
recess the wall to allow for the
concealing Plates, 3 mm diameter
x 0 mm deep.
note!
Depth must be sufficient to
prevent the concealing Plates fouling
on the plumbing elbows.
1.5
Fit the supply pipework (hot - left,
cold - right). the pipework must
project 18 mm from the finished wall
surface at 53 mm centres (use the
Installation template as a guide).
note!
If the connections are reversed,
complete the installation then refer to
section:
‘Reversed Inlet supplies’
before commissioning.
1. Rear entry supplies (rising or falling concealed pipework)
0 mm depth x Ø3 mm
for concealing Plates
53 mm
Wall
Plugs
apply Silicone
Sealant
Backplate
concealing Plates
Securing Screws
0 mm minimum
between elbow
and finished wall
surface
3 mm
8 mm from
finished wall
surface
elbow
40 mm
153 mm
Shower Control
Backplate Fixing Points
(Ø6 mm)
Bend tabs inward
s
Use as a support for the spirit level
Bend tabs inward
s
Use as a support for the spirit level
Hot Supply Inlet
(Ø15 mm)
Make sure that supply pipes are thoroughly flushed through
before connection to the shower control
Cold Supply Inlet
(Ø15 mm)
53 mm
50 mm
50 mm
40 mm