Fig.#11

11

Install fragrance porcelain
(for K-21842T-WXEW only)

1. Insert the scent top into the plug.
2. Take out the tube. Fill fragrance into

the tube. Do not overfill to avoid
overflow.

3. Insert the plug into the tube.
4. Insert the tube into the hole on the

urinal cover.

Be careful when filling

fragrance into the tube. Do not drop it
onto the electrical components to
avoid short circuit and malfunction.

Caution:

(

K-21842T-WXEW)

1.
2.

3.
4.

Notice:

The first 2 minutes with power is the standby time for

adjusting sensing distance. Persons or subjects
should avoid standing before the sensor (See Fig.2).
The sensor will not flush during.

2

(

2)

USER'S GUIDE

USER'S GUIDE

Electrolyzed Water

The urinal will take a flush Electrolyzed Water every two
hours. If the urinal is used during flushing, the electrolysed
water will stop.

2

Deodorizing Flushing

The urinal will take a flush automatically when it's used 3 or 4
times in 2 minutes.

Replacement of Batteries

When the batteries run out, please remove the Battery Box
Assembly by following the battery installation steps and then
replace the batteries.

2

3-4

-9-

MAINTENANCE

Clean the Filter Screen

If the flushing volume reclines sharply after installation or
used for a long time with no cause from water pressure, the
filter may need a wash. Please operate as following steps:
Remove the fixed cap

a. Turn off the water supply and power

supply before cleaning the filter.

b. Avoid damaging or losing the filter during

cleaning.

Caution:

and take out the filter, clean the filter

and then reinstall it.

a.

b.

Filter

Fixed Cap

Fig.12

12

1356730-T01-B

Summary of Contents for MODERN LIFE K-21842T

Page 1: ...proper installation read all operating and safety instructions All information in these instructions is based upon the latest product information available at the time of publication Kohler China rese...

Page 2: ...g Water pressure at 0 18 0 55 MPa Average no more than 1L Water pressure at 0 1 MPa no more than 1L Water pressure at 0 18 0 55 MPa no more than 3L Water pressure at 0 1 MPa no more than 3L Average Te...

Page 3: ...0 55MPa 1L 0 1MPa 1L 0 18 0 55MPa 3L 0 1MPa 3L 1 55 0 05Mpa 0 86MPa 70cm 4 3L 1L 3 ROUGHING IN Unit mm Reference Value Kohler reserves the right to change marked dimensions without prior notice Recom...

Page 4: ...Wall 150 Draw centerline Draw lines according to height of the mounting hole center Connect the right and left lines Drill holes on the center Electronic components are pre installed in factory Elect...

Page 5: ...ry case assy and loosen the screws 17 Place 4 AA batteries into the battery case according to negative and positive electrode marks on the battery case cover 18 Tighten the screws on the battery case...

Page 6: ...control box by connection wire a 220V b c A 6 Fig 4 4 AC Connector Wire prepared by customer Connector Connect with the same color wire and protect connect area by insulation tape 16305T NA AC Power U...

Page 7: ...sleeving is recommended Wire of which the nominal section area of conductor is not less than 0 5mm is also recommend DC connection line use wire of which the nominal section area is not less than 0 3...

Page 8: ...9 L 5 Fig 9 9 Fig 8 8 Flange Screw Hole Install Urinal Cover See Fig 10 NOTE CAUTION 1 Open urinal cover lock package and remove contents Fix hook and screw as shown 2 Put urinal cover on the urinal...

Page 9: ...ill take a flush Electrolyzed Water every two hours If the urinal is used during flushing the electrolysed water will stop 2 Deodorizing Flushing The urinal will take a flush automatically when it s u...

Page 10: ...2 3 1 2 3 No flushing or poor flushing 1 Adjusting bolt not fully open 2 Low water pressure 3 Filter is obstructed 1 Open the adjusting bolt 2 Improve water supply 3 Clean the filter 1 2 1 2 1 2 1 2s...

Page 11: ...treous china surface of the urinal Please follow the bowl cleaner manufacturer s instructions carefully Do not use abrasive cleaners or solvents Do not use cleaners inside the wash basin Products cont...

Reviews: