background image

-8-

2. Connect inlet pipe: Connect to the corner valve.
3. Install flange (see Fig.8, optional for purchase). Put the

urinal against wall and align the bottom with the lines
drawn.

4. Insert the screw through the screw hole (see Fig.9) Into the

L-shaped fixing block. Tighten the screw.

5. Apply silicone sealant between the urinal and the wall.

2.
3.

(

8

)

4.

(

9)

L

5.

Fig.9

9

Fig.8

8

Flange

Screw Hole

Install Urinal Cover

See Fig.#10

NOTE:

CAUTION:

1. Open urinal cover lock package and remove contents. Fix

hook and screw as shown.

2. Put urinal cover on the urinal.
3. Use supplied locking tool to install and tighten the screw.
4. Check that the urinal cover is properly locked.

Using a 5/8" wrench, assemble and tighen nut,

washer and lock nut on both sides of urinal.

Risk of chipping or breaking urinal. Do not

overtighen screws on urinal.

10

1.

2.
3.
4.

5/8"

Hook

Nut

Washer

Screw

Sleeve

Fig.10

10

1356730-T01-B

Summary of Contents for MODERN LIFE K-21842T

Page 1: ...proper installation read all operating and safety instructions All information in these instructions is based upon the latest product information available at the time of publication Kohler China rese...

Page 2: ...g Water pressure at 0 18 0 55 MPa Average no more than 1L Water pressure at 0 1 MPa no more than 1L Water pressure at 0 18 0 55 MPa no more than 3L Water pressure at 0 1 MPa no more than 3L Average Te...

Page 3: ...0 55MPa 1L 0 1MPa 1L 0 18 0 55MPa 3L 0 1MPa 3L 1 55 0 05Mpa 0 86MPa 70cm 4 3L 1L 3 ROUGHING IN Unit mm Reference Value Kohler reserves the right to change marked dimensions without prior notice Recom...

Page 4: ...Wall 150 Draw centerline Draw lines according to height of the mounting hole center Connect the right and left lines Drill holes on the center Electronic components are pre installed in factory Elect...

Page 5: ...ry case assy and loosen the screws 17 Place 4 AA batteries into the battery case according to negative and positive electrode marks on the battery case cover 18 Tighten the screws on the battery case...

Page 6: ...control box by connection wire a 220V b c A 6 Fig 4 4 AC Connector Wire prepared by customer Connector Connect with the same color wire and protect connect area by insulation tape 16305T NA AC Power U...

Page 7: ...sleeving is recommended Wire of which the nominal section area of conductor is not less than 0 5mm is also recommend DC connection line use wire of which the nominal section area is not less than 0 3...

Page 8: ...9 L 5 Fig 9 9 Fig 8 8 Flange Screw Hole Install Urinal Cover See Fig 10 NOTE CAUTION 1 Open urinal cover lock package and remove contents Fix hook and screw as shown 2 Put urinal cover on the urinal...

Page 9: ...ill take a flush Electrolyzed Water every two hours If the urinal is used during flushing the electrolysed water will stop 2 Deodorizing Flushing The urinal will take a flush automatically when it s u...

Page 10: ...2 3 1 2 3 No flushing or poor flushing 1 Adjusting bolt not fully open 2 Low water pressure 3 Filter is obstructed 1 Open the adjusting bolt 2 Improve water supply 3 Clean the filter 1 2 1 2 1 2 1 2s...

Page 11: ...treous china surface of the urinal Please follow the bowl cleaner manufacturer s instructions carefully Do not use abrasive cleaners or solvents Do not use cleaners inside the wash basin Products cont...