13
1478624-W2-A
Evoco Dual
Blanking
Plugs
Cap
Push and hold the collet before removing the blanking plugs.
Important! DO NOT remove the cap for Dual Outlet product.
Push fit the inlet and outlet pipework into the Building In Box. Hold the box securely
while fixing the pipework. Insert the locking clips (supplied) to secure the pipes in place.
COLD
HOT
Important! Cut the pipe using a pipe cutter only to ensure the seals
are not damaged when the pipe is inserted. Remove all burrs.
Note: Grease sachets are supplied and a small amount should be applied to
the end of the pipe to aid insertion.
Warning! Mark each piece of pipework at 36mm. The push-fit connections
contain seals (x2). Make sure you push the pipes in the full 36mm as indicated
to completely engage (you should feel the pipes push past both seals when
you do this). There is a risk of leaking if pipe work not fully pushed into the
connector.
Locking
Clips
Insert locking
clip here
Evoco Triple
Blanking
Plugs
Blanking
Plug
36mm
Collet