- 61 -
6
146
147
97-68 CE
2400
9° ± 1°
8° --> 0.56
9° --> 0.71
10° --> 0.87
2500 ÷ 2800
8° ± 1°
7° --> 0.43
8° --> 0.56
9° --> 0.71
3000
9° ± 1°
8° --> 0.56
9° --> 0.71
10° --> 0.87
EPA
2400 ÷ 2800
5° ± 1°
4° --> 0.14
5° --> 0.22
6° --> 0.32
1500 ÷ 2200 14° ± 1°
13° --> 1.47
14° --> 1.71
15° --> 1.96
2201 ÷ 3000 16° ± 1°
15° --> 1.47
16° --> 1.71
17° --> 1.96
α
(mm)
0°
0.00
1°
0.01
2°
0.04
3°
0.08
4°
0.14
5°
0.22
6°
0.32
7°
0.43
8°
0.56
9°
0.71
10°
0.87
11°
1.06
12°
1.26
13°
1.47
14°
1.71
15°
1.96
16°
2.22
17°
2.51
18°
2.81
19°
3.12
20°
3.45
The capillary tube shows when the fuel is flowing out, thanks to its
small transparent slot.
Table static advance values for engines with P size injectors
Fuel system
Table static advance values for engines with S size injectors
Conversion table from degrees
into millimetres
After finding the delivery start point (when fuel stops flowing from the
capillary), press the lever and use the dial indicator to check how
many millimetres the piston has moved from the top dead centre.
Check static injection advance using the conversion table from milli-
metres to degrees.
If it is necessary to change static advance add the seals
G
in figure
129 (to delay) or remove the seals
G
in figure 129 (to advance) from
between the injection pump surface and the crankcase surface.
The same operation must be performed for each cylinder.
R.p.m.
α
Piston lowering (mm)
R.p.m.
α
Piston lowering (mm)
KD Workshop Manual_cod. ED0053029350_
1° ed
_ rev.
00
Summary of Contents for KD 626/3
Page 1: ...KD 625 3 626 3 WORKSHOP MANUAL...
Page 21: ...21 3 KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...
Page 69: ...69 NOTES KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...
Page 70: ...70 NOTES KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...
Page 99: ...99 NOTES KD Workshop Manual_cod ED0053029350_1 ed_ rev 00...