5 — MONITOR PARAMETERS
pg. 45
Curtis Model 3401T – August 2022
OUTPUT MENU
The following table describes the parameters on the Output menu. These parameters are used when
pin 8 is configured as a MOSFET driver.
OUTPUT MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DESCRIPTION
PWM Duty
0x6700:00
0.0–100.0%
0–1000
16-bit
Field
Intermediate
Indicates the PWM percentage when pin 8 is
configured as a driver.
Current
0x66E0:00
0–1000mA
0–1000
16-bit
Field
Intermediate
Indicates the output current when the
parameter specifies Current Mode.