4 — PROGRAMMABLE PARAMETERS
Curtis Model 3401T – August 2022
pg. 38
PASSWORD MENU
The Password parameters specify the passwords for powering on the 3401T and for
.
Note: The passwords’ ranges of values are 11111–55555. However, passwords can only consist of the
digits 1 through 5.
PASSWORD MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
OEM Menu Password
0x6011:00
11111–55555
11111–55555
32-bit
OEM Dealer
22222
Specifies the password for accessing parameter
menus that have the OEM access level.
USER Menu Password
0x600F:00
11111–55555
11111–55555
32-bit
Field Intermediate
11111
Specifies the password for accessing parameter
menus that have the User access level.
PIN Code
0x6010:00
11111–55555
11111–55555
32-bit
Field Intermediate
12345
Specifies the password for powering on the 3401T.
Note
: The
whether a password is required.
MAINTENANCE MENU
The 3401T provides three countdown maintenance monitors. The Maintenance parameters specify
intervals for and reset the monitors.
Note: The parameters on the
of the Monitor menu indicate how much time
remains on the maintenance monitors.
MAINTENANCE MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Maintenance Interval 1
0x643E:00
0.0–3276.7 hours
0–32767
32-bit
Field Intermediate
999.9 hours
Specifies the countdown interval for maintenance
monitor 1.
Maintenance Interval 2
0x6444:00
0.0–3276.7 hours
0–32767
32-bit
Field Intermediate
999.9 hours
Specifies the countdown interval for maintenance
monitor 2.
Maintenance Interval 3
0x644A:00
0.0–3276.7 hours
0–32767
32-bit
Field Intermediate
999.9 hours
Specifies the countdown interval for maintenance
monitor 3.
Reset Maintenance
Interval 1
0x6471:00
Off/On
0–1
16-bit
Field Intermediate
Off
Resets maintenance monitor 1.
Reset Maintenance
Interval 2
0x6472:00
Off/On
0–1
16-bit
Field Intermediate
Off
Resets maintenance monitor 2.
Reset Maintenance
Interval 3
0x6473:00
Off/On
0–1
16-bit
Field Intermediate
Off
Resets maintenance monitor 3.