![Kohler CURTIS 3401T Manual Download Page 45](http://html.mh-extra.com/html/kohler/curtis-3401t/curtis-3401t_manual_1988885045.webp)
4 — PROGRAMMABLE PARAMETERS
pg. 39
Curtis Model 3401T – August 2022
ODOMETERS MENU
The 3401T provides three odometers. The Odometers parameters reset the odometers.
Note: The parameters on the
of the Monitor menu indicate the odometer data.
ODOMETERS MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Reset Odometer 1
0x646E:00
Off/On
0–1
16-bit
Field Intermediate
Off
Resets odometer 1 to 0.
Reset Odometer 2
0x646F:00
Off/On
0–1
16-bit
Field Intermediate
Off
Resets odometer 2 to 0.
Reset Odometer 3
0x6470:00
Off/On
0–1
16-bit
Field Intermediate
Off
Resets odometer 3 to 0.
SENDERS MENU
The Senders parameters specify the types of data received by the
.
SENDERS MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES
DATA SIZE
ACCESS LEVEL
DEFAULT VALUE
DESCRIPTION
Sender 1 Type
0x6300:00
Enumerated
0–3
32-bit
Field Intermediate
0
Configures the switch 1 input:
0 = Switch Input
1 = Resistor Input
2 = Voltage Input
3 = Frequency Input
(reserved)
Sender 2 Type
0x6301:00
Enumerated
0–3
32-bit
Field Intermediate
0
Configures the switch 2 input:
0 = Switch Input
1 = Resistor Input
2 = Voltage Input
3 = Frequency Input
(reserved)
Sender 3 Type
0x6302:00
Enumerated
0–3
32-bit
Field Intermediate
3
Configures the switch 3 input:
0 = Switch Input
1 = Resistor Input
2 = Voltage Input
3 = HYD Fault Input (Curtis DC pump controller)
Sender 4 Type
0x6303:00
Enumerated
0–3
32-bit
Field Intermediate
3
Configures the switch 4 input:
0 = Switch Input
1 = Resistor Input
2 = Voltage Input
3 = TRA Fault Input (Curtis DC traction controller)