2

Remove the old gasket from the floor
and the closet flange with a putty knife.
Remove the old T-bolts and discard
them.

if the new toilet is not

installed immediately, temporarily stuff
a rag into the closet flange.

NOTICE:

T

NOTICE:

Do not use white cement or high lime content

cements to install this toilet. The expansion of cement due to
a rise in temperature may make the toilet crack or cause
damage. Kohler is not responsible for any damage caused by
installation with the use of cement.

Closet Flange

TO REMOVE EXISTING TOILET

Turn off the water supply. Flush the toilet, and use a sponge
to remove the remaining water from the tank and bowl.
Disconnect the supply shut-off valve (if present), and remove
the old tank and bowl.

(

)

INSTALLATION

Kohler reserves the right to change marked dimensions without prior notice.

Fig.#1

1

749

392

708

390

67

200

400

Finished Wall

FRONT OF BOWL

K-4165T-S/K-4165T-SE/K-4165T-NSE

Unit: mm

:

Reference Value

K-3869T-S/K-3869T-SE/K-3869T-NSE

OF OUTLET

CL

FRONT OF BOWL

Finished Wall

305

390

708

67

200

749

392

1195897-T01-G

Summary of Contents for AERODYNE K-3869T-S

Page 1: ...NE 3 3 4 8L CLASS FIVE 1 PC Toilet 305mm K 3869T S Includes Quiet Close Toilet Seat K 4141T 2P AERODYNE 3 3 4 8L CLASS FIVE 1 PC Toilet 400mm K 4165T S Includes Quiet Close Toilet Seat K 4141T 2P AERODYNE 3 3 4 8L CLASS FIVE 1 PC Toilet 305mm K 3869T SE Includes Quiet Close Toilet Seat K 4141T 2P AERODYNE 3 3 4 8L CLASS FIVE 1 PC Toilet 400mm K 4165T SE Includes Quiet Close Toilet Seat K 4141T 2P ...

Page 2: ...ut has been factory tightened to design specifications If re tightening is required wrench tighten one turn past finger tight NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm 5 1 2 centers 51mm 2 passageway Water depth from the rim is 160mm Ensure that the new drain has the correct roughing in dimension This toilet has a 305 400mm roughing ...

Page 3: ...sponsible for any damage caused by installation with the use of cement Closet Flange TO REMOVE EXISTING TOILET Turn off the water supply Flush the toilet and use a sponge to remove the remaining water from the tank and bowl Disconnect the supply shut off valve if present and remove the old tank and bowl INSTALLATION Kohler reserves the right to change marked dimensions without prior notice Fig 1 1...

Page 4: ...own the position of foot and 5 holes Drain Hole Fig 5 5 3 8 10mm 10mm 5 Drill holes on ground with the drill of 10mm 3 8 then insert anchor to holes CAUTION Please make sure there is no water pipe or spool under the 5 holes to be drilled mm 67mm 67 mm 194 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 67mm 2 5 8 above the finished floor line and 194mm 7 5 8 to ...

Page 5: ...let insert into plastic trap Outlet Plastic Trap Fig 10 10 Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent pulling the toilet off center Install cap to cover screw Do not overtighten Cap Screw Bushing Fig 11 11 Fig 8 8 Install plastic to ground and mounted with 3 set of bolts not supplied firmly 3 Fig 9 9 Connect flexible hos...

Page 6: ...gid connection must be fit with supply line completely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve Fig 14 14 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and rust from the system Mak...

Page 7: ...ows 7 Toilet does not activate A Reconnect the push button A Push button is not connected to lift rod or flush valve 2 Fill valve continues to run allowing water to enter tank 3 Incorrect water level height A Foreign particles lodged under the float valve seal located under fill valve cap B Fill valve seal located under float valve cap may be cracked or split C Water leaking past flush ball D Flap...

Page 8: ... cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C o ...