Firmly press the toilet gasket onto the
toilet outlet of plastic trap.

Wax ring type toilet gasket

should not be installed at temperatures
less than 21 C.

If you are using a toilet

gasket with an integral plastic sleeve,
make sure the gasket is positioned
with the sleeve facing away from the
toilet.

NOTE 1:

NOTE 2:

o

1

21

2

o

C

Install brackets.

Fig.#7

7

Plastic Trap Outlet

Toilet Gasket

Fig.#6

6

Fig.#4

4

TO INSTALL BOWL

Position the template and align with
drain hole.

Mark down the position of foot and 5
holes.

Drain Hole

Fig.#5

5

3/8

10mm

10mm

5

Drill holes on ground with the drill of
10mm (3/8"), then insert anchor to
holes.

CAUTION:

Please make sure there is

no water pipe or spool under the 5
holes to be drilled.

mm

67mm;

67

mm

194

Fig.#3

3

TO INSTALL SUPPLY
SHUT-OFF VALVE

Install the supply shut-off valve so it is
67mm (2-5/8") above the finished floor
line, and 194mm (7-5/8") to the left of
the closet flange centerline.

The centerline of the supply shut-off
valve outlet should extend 67mm
(2-5/8") from the finished wall. Install
the supply shut-off valve with the outlet
vertical.

Supply Shut-Off Valve

Closet Flange
Centerline

200

305/400

67

1195897-T01-G

Summary of Contents for AERODYNE K-3869T-S

Page 1: ...NE 3 3 4 8L CLASS FIVE 1 PC Toilet 305mm K 3869T S Includes Quiet Close Toilet Seat K 4141T 2P AERODYNE 3 3 4 8L CLASS FIVE 1 PC Toilet 400mm K 4165T S Includes Quiet Close Toilet Seat K 4141T 2P AERODYNE 3 3 4 8L CLASS FIVE 1 PC Toilet 305mm K 3869T SE Includes Quiet Close Toilet Seat K 4141T 2P AERODYNE 3 3 4 8L CLASS FIVE 1 PC Toilet 400mm K 4165T SE Includes Quiet Close Toilet Seat K 4141T 2P ...

Page 2: ...ut has been factory tightened to design specifications If re tightening is required wrench tighten one turn past finger tight NOTES Observe all local plumbing and building codes Shut off the water supply Seat post holes are on 140mm 5 1 2 centers 51mm 2 passageway Water depth from the rim is 160mm Ensure that the new drain has the correct roughing in dimension This toilet has a 305 400mm roughing ...

Page 3: ...sponsible for any damage caused by installation with the use of cement Closet Flange TO REMOVE EXISTING TOILET Turn off the water supply Flush the toilet and use a sponge to remove the remaining water from the tank and bowl Disconnect the supply shut off valve if present and remove the old tank and bowl INSTALLATION Kohler reserves the right to change marked dimensions without prior notice Fig 1 1...

Page 4: ...own the position of foot and 5 holes Drain Hole Fig 5 5 3 8 10mm 10mm 5 Drill holes on ground with the drill of 10mm 3 8 then insert anchor to holes CAUTION Please make sure there is no water pipe or spool under the 5 holes to be drilled mm 67mm 67 mm 194 Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 67mm 2 5 8 above the finished floor line and 194mm 7 5 8 to ...

Page 5: ...let insert into plastic trap Outlet Plastic Trap Fig 10 10 Carefully thread the screws into the brackets until toilet is secure Alternately tighten left and right sides to prevent pulling the toilet off center Install cap to cover screw Do not overtighten Cap Screw Bushing Fig 11 11 Fig 8 8 Install plastic to ground and mounted with 3 set of bolts not supplied firmly 3 Fig 9 9 Connect flexible hos...

Page 6: ...gid connection must be fit with supply line completely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve Fig 14 14 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and rust from the system Mak...

Page 7: ...ows 7 Toilet does not activate A Reconnect the push button A Push button is not connected to lift rod or flush valve 2 Fill valve continues to run allowing water to enter tank 3 Incorrect water level height A Foreign particles lodged under the float valve seal located under fill valve cap B Fill valve seal located under float valve cap may be cracked or split C Water leaking past flush ball D Flap...

Page 8: ... cleaners or solvents Do not use in tank cleaners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage 0 C o ...