6
1095640-W2-B
SPECIFICATIONS
Pressures and Flow Rates
Note!
For optimum performance, dynamic supply pressures should be nominally
equal.
Recommended Minimum Dynamic Supply Pressure:
0.15 bar.
Recommended Maximum Dynamic Supply Pressure:
5 bar.
Maximum Static Pressure:
10 bar.
Recommended Minimum Flow Rate:
3 L/min at mid-blend with equal dynamic
supply pressures.
Recommended Maximum Flow Rate:
35 L/min at mid-blend (which equates to
maximum pressure loss of 1.8 bar).
Temperatures
Optimum performance is obtained when temperature differentials of 20°C or more
exist between blend and either supply. Blend control accuracy will begin to diminish
at temperature differentials below 12°C.
Blend Temperature Range:
between ambient cold and approximately 60°C,
according to hot water supply temperature.
Thermostatic Control Range:
approximately 25-60°C.
Optimum Thermostatic Control Range:
30-50°C.
Recommended Minimum Cold Water Temperature:
1°C.
Recommended Maximum Hot Water Supply Temperature:
85°C.
Connections
Inlets and Outlet: 1/2” BSP external union or 15 mm compression.
Pressure Loss (bar)
Flow Rate (L/Min)
0.5
1.0
1.5
2.0
0
0
10
20
30
40
50
Summary of Contents for 1190330-NA