13
1095640-W2-B
Screws
Outlet Pipe
to Fittings
Hot Supply
Cold
Supply
Finished Wall
F15295/1
Min
Max
Minimum finished
wall surface
Maximum finished
wall surface
9.
Fit the hot and cold supply pipework
(Hot - Left, Cold - Right).
Caution! It is essential at this
point that the supply pipework
is thoroughly flushed through
before connection to the mixer.
Failure to do so may result in product
malfunction and will not be covered
under the guarantee.
10.
Insert the wall plugs (supplied) and
attach the mixer to the wall with the
screws provided.
Note!
For stud partition installations
alternative fixings may be required
(not supplied) to fix the mixer to the
rear face of the wall cavity or to a
timber noggin.
11.
Make sure that the olives are fitted,
connect the hot and cold supply pipes
and tighten the compression nuts.
12.
Connect the outlet pipework, leaving
enough pipe through the wall to
temporarily cap off.
13.
Turn on the water supplies and check
for leaks.
14.
Attach the building-in shroud to the
mixer using the shroud screw removed
earlier.
15.
Using the ‘Finished Wall’ indicator
on the building-in shroud as a guide,
finish the wall, e.g. tiles.
Caution!
Make sure that the finished
wall is within the maximum and
minimum limits and to an even depth
(no greater than 2 mm variation) or
the control components will not fit
correctly.