background image

1

1095640-W2-B

IMPORTANT 

INSTALLER:

 THIS MANUAL IS THE PROPERTY OF THE 

CUSTOMER AND MUST BE RETAINED WITH THE PRODUCT 

FOR MAINTENANCE AND OPERATIONAL PURPOSES.

Installation and User Guide

Built-In Shower Valve

MODEL NUMBERS

Important! 

Please quote the above model number(s) when ordering spares

1190330-NA, 998W-K-NA

Temperature Only

Single Sequential

Summary of Contents for 1190330-NA

Page 1: ...TOMER AND MUST BE RETAINED WITH THE PRODUCT FOR MAINTENANCE AND OPERATIONAL PURPOSES Installation and User Guide Built In Shower Valve MODEL NUMBERS Important Please quote the above model number s whe...

Page 2: ...res and Flow Rates 6 Dimensions 7 Installation 8 Suitable Plumbing Systems 8 General 8 Reversing the Outlet Position 10 Installation Procedure 11 Operation 15 Commissioning 16 Maximum Temperature Sett...

Page 3: ...ith these instructions and must be conducted by designated qualified and competent personnel 4 Pass on this guide in the event of change of ownership of the installation site 5 Follow all warnings cau...

Page 4: ...ppliance to thaw and check for leaks before using 17 Insulate any pipework that could be exposed to freezing conditions 18 The water supplies to this product must be isolated if the product is not to...

Page 5: ...5 1095640 W2 B PACK CONTENTS Or q 1 x Mixer Valve Single Sequential Temperature Only q 1 x Building in Shroud q 1 x Adapter Pack q 3 x Screws q 3 x Wall Plugs...

Page 6: ...mperatures Optimum performance is obtained when temperature differentials of 20 C or more exist between blend and either supply Blend control accuracy will begin to diminish at temperature differentia...

Page 7: ...7 1095640 W2 B DIMENSIONS All dimensions are nominal and in mm 140 16 77 140 53 Single Sequential Temperature Only 16 77 53...

Page 8: ...se instructions and must be conducted by designated qualified and competent personnel The installation must comply with the Water Supply Regulations 1999 Water Fittings or any particular regulations a...

Page 9: ...on or if the product is dismantled during installation or servicing then the product must be inspected to ensure that there are no leaks 14 Having completed the installation make sure that the user is...

Page 10: ...d 2 Remove the outlet blanking plug using a 12 mm hexagonal wrench 3 Screw the outlet adapter complete with O seal into the bottom hole previously blanked and tighten 4 Screw the outlet blanking plug...

Page 11: ...e side of the mixer This is to prevent the flexible hose from obstructing the shower controls 2 Remove the shroud screw retain for later use and remove the mixer from the building in shroud 3 Determin...

Page 12: ...ting e g timber noggin to the front of the wall before tiling 7 Make sure that the mixer is level central in the hole and square to the finished wall surface or the control components will not fit cor...

Page 13: ...nstallations alternative fixings may be required not supplied to fix the mixer to the rear face of the wall cavity or to a timber noggin 11 Make sure that the olives are fitted connect the hot and col...

Page 14: ...nly The Temperature Adapter must be fitted before the trim kit 19 1 Fit the Spline Adapter to the cartridge 19 2 Fit the retaining screw into the centre of the spline adapter Tighten the screw 19 3 Fi...

Page 15: ...Turning the control knob anti clockwise will increase the flow and temperature from off through cold to the preset maximum Temperature Only Turning the control knob anti clockwise will increase the t...

Page 16: ...Adapter until the grubscrew can be seen in the cutout then unscrew the grubscrew approx 2 turns 3 2 Remove the temperature adapter and the adapter ring 3 3 Unscrew and remove the Hub Retaining Screw...

Page 17: ...17 1095640 W2 B Hub Retaining Screw Temperature Adapter Single Sequential Temperature Only Cartridge Drive Adapter Maximum Temperature Setting Cartridge Adapter Ring Adapter Cutout Grubscrew...

Page 18: ...tory a Check strainers and inlet outlet fittings for flow restriction b Make sure that the minimum flow rate is sufficient for the supply conditions c Make sure that the dynamic inlet pressures are no...

Page 19: ...icant types may cause rapid deterioration of seals Cleaning The chrome plated parts should be cleaned using a mild washing up detergent or soap solution rinsed and then wiped dry with a soft cloth War...

Page 20: ...ing of residual water 4 Continue to unscrew and remove the non return valve assembly Caution Some residual water may be released 5 The non return valve assembly and or strainer screens can be cleaned...

Page 21: ...pplied 1595 070 Component Pack identified A 1624 102 Screw Pack identified B 1624 109 Seal Pack identified C 408 71 Flat Faced Insert 1624 113 Outlet Adaptor 1624 114 Blanking Plug 1624 110 Filter Non...

Page 22: ...22 1095640 W2 B NOTES...

Page 23: ...23 1095640 W2 B NOTES...

Page 24: ...esolve any material defects by providing replacement parts modules or complete product as we deem appropriate To be free of charge work must be undertaken by Kohler approved personnel To ensure that a...