background image

KOGANEI  CORP.  shall  in  no  way  be  liable  or  responsible  for 
injuries or damage to persons or property arising out of the use 
or operation of the manufacturer’s product.

This  warranty  shall  be  void  if  the  engineered  safety  devices  
are removed, made inoperative or not periodically checked for 
proper functioning.

Any operation beyond the rated capacity, any improper use or 
application, or any improper installation of the product, or any 
substitution  upon  it  with  parts  not  furnished  or  approved  by 
KOGANEI CORP., shall void this warranty.

This  warranty  covers  only  such  items  supplied  by  KOGANEI 
CORP.  The  products  of  other  manufacturers  are  covered  only  
by  such  warranties  made  by  those  original  manufacturers,  even 
though such items may have been included as the components.

The specifications are subject to change without notice.

Limited Warranty

KOGANEI CORP. warrants its products to be free from defects
in material and workmanship subject to the following provisions.

The warranty period is 180 days from the date 
of delivery.

If a defect in material or workmanship is found 
during  the  warranty  period,  KOGANEI  CORP. 
will  replace  any  part  proved  defective  under 
normal use free of charge and will provide the 
service necessary to replace such a part.

This warranty is in lieu of all other warranties, 
expressed  or  implied,  and  is  limited  to  the 
original  cost  of  the  product  and  shall  not 
include  any  transportation  fee,  the  cost  of 
installation  or  any  liability  for  direct,  indirect 
or  consequential  damage  or  delay  resulting 
from the defects.

Warranty Period

Koganei  
Responsibility

Limitations

Summary of Contents for iB-Cyclone IBCY30 Series

Page 1: ...ISO 9001 ISO 14001 Catalog No BK E0007 PAT PEND Introducing the high speed cyclone type water separator Conceptual image of water separation Products are RoHS compliant ...

Page 2: ...erformance in a wide range of flow rates Wide range of flow rates Specifications for ozone resistance NCU specifications copper free compatible as standard Compatible in a wide range of environments High speed cyclone water separator uses the power of centrifugal separation patent pending Cyclone system PAT PEND Removing water droplets using high speed cyclone Introducing the high speed cyclone type ...

Page 3: ...d solids for iB Cyclone use Variations and Options Auto drain type NO Normally open NC Normally closed Drain cock with fitting 100 90 80 70 60 50 40 0 500 Flow rate ℓ min ANR Water separation characteristics applied pressure 0 5 Mpa 73 psi 1000 1500 2000 Water separation ratio Drain filter DF300 conventional product iB Cyclone IBCY40 Drain filter DF600 conventional product 1ℓ min 0 0353 ft3 min Th...

Page 4: ...e or functions This can lead to injury etc While the product is in operation avoid touching it with your hands or otherwise approaching too close except for specified operations Also do not attempt to make any adjustments to internal or attached mechanisms or to perform any type of adjustment disconnecting tubes or sealed plugs adjustment of the product s mounting position etc while the product is...

Page 5: ...roduct by climbing on it using it as a scaffold or placing objects on top of it Doing so creates the risk of damage to or breakage of the product resulting in operational shutdown or degraded performance Always be sure to post an operation in progress sign during installation adjustment or other operations to avoid unintended air supply Unintentional supplying of air can cause sudden operation and...

Page 6: ...ment and vibration are easily transmitted from steel or non flexible piping place a flexible hose between the product and the piping to prevent this from affecting the product Flow mark Main unit IBCY30 IBCY40 IBCY50 IN OUT IN OUT Connecting thread 1 8 1 4 3 8 1 2 Torque 7 9 5 2 6 6 12 14 8 9 10 3 22 24 16 2 17 7 28 30 20 7 22 1 N m ft lbf Recommended tightening torque 1 Install in a location wher...

Page 7: ...e that is under 5 m 16 4 ft 3 If you are using the auto drain type the water that collects on the primary side is flushed all at once If collected water exceeds the maximum level in the right of the diagram below it could lead to a malfunction Be careful that it does not exceed the maximum level 1 Dust collecting in the whirling air components reduces the separation function If this happens disass...

Page 8: ... the drain knob counterclockwise See page for details When the level of water in the bowl reaches a specified level the float lifts and the water automatically drains Note 1 Supply pressure is needed to operate the auto drain A minimum of 0 15 MPa 22 psi is needed for the supply pressure 2 Water can be drained manually by turning the drain knob counterclockwise See page for details Draining water co...

Page 9: ...chloroethylene carbon tetrachloride Organic solvents for metal cleaning trichlene tetrachloroethylene carbon tetrachloride Chlorinated aromatic hydrocarbons Chlorobenzene dichlorobenzene benzene hexachloride BHC Agricultural chemicals Petroleum components Solvent naphtha gasoline Fuel Alcohol Methyl alcohol ethyl alcohol cyclohexanol benzyl alcohol Anti freezing agents Phenol Carbolic acid cresol ...

Page 10: ...4 Bracket Blank No bracket B With bracket Drain cock specifications A NO type auto drain drain cock C NC type auto drain drain cock N Drain cock with fitting Drain cock specifications A NO type auto drain drain cock C NC type auto drain drain cock N Drain cock with fitting Body size 30 for IBCY30 40 for IBCY40 50 for IBCY50 Body size 30 for IBCY30 40 for IBCY40 50 for IBCY50 Maintenance parts Orde...

Page 11: ...0 1MPa 0 1MPa 0 3MPa 0 3MPa 0 3MPa 0 3MPa 0 3MPa 0 3MPa 0 3MPa 0 5MPa 0 5MPa 0 5MPa 0 5MPa 0 5MPa 0 5MPa 0 5MPa 0 7MPa 0 7MPa 0 7MPa 0 7MPa 0 7MPa 0 7MPa 0 7MPa 0 1MPa 0 3MPa 0 5MPa 0 7MPa 0 100 200 0 500 1500 1000 ℓ min ANR mℓ min mℓ min Flow rate 0 100 200 0 1000 3000 2000 ℓ min ANR Flow rate 0 100 200 300 300 0 1000 3000 2000 ℓ min ANR mℓ min mℓ min Flow rate 0 100 200 0 500 2500 1000 1500 2000...

Page 12: ...34 175 6 89 165 6 50 IBCY30 01 Rc1 8 IBCY30 02 Rc1 4 38 1 50 35 1 38 19 0 75 19 0 75 φ4 5 0 177 D R A I N φ4 5 0 177 32 1 26 25 0 98 29 1 14 6 5 0 256 179 7 05 175 6 89 189 7 44 45 1 77 IBCY40 01 Rc1 8 IBCY40 02 Rc1 4 IBCY40 03 Rc3 8 Maintenance space 40 1 57 or over I N OUT 40 1 57 50 1 97 22 5 0 886 35 1 38 D R A I N φ4 5 0 177 ...

Page 13: ...07 I N OUT 35 1 38 54 2 13 27 1 06 IBCY50 02 Rc1 4 IBCY50 03 Rc3 8 IBCY50 04 Rc1 2 Maintenance space 50 1 97 or over D R A I N φ4 5 0 177 5 0 20 5 5 0 217 36 1 42 32 1 26 24 0 94 14 0 55 6 5 0 256 φ 2 8 1 1 0 54 5 2 15 35 1 38 52 5 2 067 50 1 97 2 0 08 3 34 1 34 7 0 28 M28 1 5 Mounting ring Bracket ...

Page 14: ... Memo ...

Page 15: ...nufacturers even though such items may have been included as the components The specifications are subject to change without notice Limited Warranty KOGANEI CORP warrants its products to be free from defects in material and workmanship subject to the following provisions The warranty period is 180 days from the date of delivery If a defect in material or workmanship is found during the warranty pe...

Page 16: ...gda Venture Building No 1 Lane 600 Tianshan Road Shanghai 200051 China Tel 86 21 6145 7313 Fax 86 21 6145 7323 KOGANEI KOREA CO LTD KT G Cosmo Bldg 3F 40 13 Maesanno 2 ga Paldal gu Suwon si Gyeonggi do 442 847 Korea Tel 82 31 246 0414 Fax 82 31 246 0415 KOGANEI PORNCHAI CO LTD 3300 90 Tower B Elephant Tower 16th Fl Phaholyothin Road Chomphon Chatuchak Bangkok 10900 Thailand Tel 66 2 937 4250 Fax 6...