Chapter 2 Radar Basic Operation MDC-5200/5500 Series
0093155002-00
2-46
Remote cable
CW-561-**M
DUAL MASTER
Control cable
DUAL SLAVE
CW-373-**M
Remote cable
CW-561-**M
Control cable
CROSS
CW-373-**M
DUAL MASTER: Connection topology is the same as the above-mentioned INDEPENDENT
(MASTER) and INDEPENDENT (SLAVE), and the control cable is necessary.
By this way, either radar can control the antenna. The radar to which the antenna is
connected is DUAL (MASTER).
DUAL SLAVE: The radar to which the antenna is not connected is DUAL (SLAVE).
CROSS: In this status, there are two radars to which each antenna is connected.
In this status, the antenna that is not connected to its own radar is used.
MONITOR: In this status, the antenna is not connected, and a simulator is connected and used.
Note: When you use inter-switch mode at first time, please set Heading (HL OFFSET), TX DELAY and
ANT CABLE adjustment of each antenna. (Refer to 4.2.2, 4.2.3 and 4.2.4 of Installation manual)
These setting data are memorized in non-volatile memory, and applied automatically when each
antenna is selected.
Summary of Contents for MDC-5200 SERIES
Page 1: ......
Page 2: ......
Page 84: ... This page intentionally left blank ...
Page 118: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 146: ... This page intentionally left blank ...
Page 152: ... This page intentionally left blank ...
Page 160: ... This page intentionally left blank ...
Page 164: ...Chapter 10 Specifications MDC 5200 5500 Series 0093155002 00 10 4 RB806 RB807 Unit mm inch ...
Page 165: ...MDC 5200 5500 Series Chapter 10 Specifications 0093155002 00 10 5 RB808 RB809 Unit mm inch ...
Page 166: ... This page intentionally left blank ...
Page 178: ... This page intentionally left blank ...
Page 182: ......