Chapter 2 Radar Basic Operation MDC-5200/5500 Series
0093155002-00
2-24
Using the EBL/VRM OFFSET
EBL (and VRM) base point can be changed to any position other than the initial reference point.
By changing the base point, the bearing from a random target can be measured.
1
Display the EBL (and VRM) for which the base point is required to be changed.
2
Move the cursor to new position.
3
Press EBL/VRM knob or EBL knob, and the base point of EBL (and VRM) changes.
During offset, the color of [OFFSET lamp] at the lower right of EBL knob changes from green to red.
(MDC-5500 series only)
The “TM” or “RM” mark is added right of the numerical figures.
“TM” means true motion, and “RM” means relative motion of OFFSET EBL1 and EBL2.
The motion selection can be changed by [NAV TOOL] => [EBL] => [EBL1 OFFSET] or
[EBL2 OFFSET] => select [RM] or [TM], and press ENT key.
4
Press EBL/VRM knob or EBL knob again, and the base point returns to the reference point.
VRM cannot offset alone.
When [NAV TOOL] => [VRM] => [OFFSET] => [ON] is selected, the base point can change a position
same as EBL.
EBL1
CURSOR
eference point
EBL1 060.5
゚
EBL2 060.5
゚
Own ship
position
Push
EBL knob
OFFSET EBL true or relative motion mark
Press
Summary of Contents for MDC-5200 SERIES
Page 1: ......
Page 2: ......
Page 84: ... This page intentionally left blank ...
Page 118: ... This page intentionally left blank ...
Page 134: ... This page intentionally left blank ...
Page 146: ... This page intentionally left blank ...
Page 152: ... This page intentionally left blank ...
Page 160: ... This page intentionally left blank ...
Page 164: ...Chapter 10 Specifications MDC 5200 5500 Series 0093155002 00 10 4 RB806 RB807 Unit mm inch ...
Page 165: ...MDC 5200 5500 Series Chapter 10 Specifications 0093155002 00 10 5 RB808 RB809 Unit mm inch ...
Page 166: ... This page intentionally left blank ...
Page 178: ... This page intentionally left blank ...
Page 182: ......