The following section outlines the actions which should be taken by the
users and system administrators when an operator message appears in
the status display.
If a message appears in the Status Display which is within the ranges
E000-E299 or E500-E599, you should take the action indicated in the
table(s) which appear in this section.
IMPORTANT:
Never power down the machine without first contacting
your System Administrator.
If a message appears in the Status Display which is within the ranges
E300-E499 or E600-E999, you should contact your System
Administrator.
If a message appears in the Status Display which is within the ranges
E300-E499 or E600-E999, you should be contacted by the operator.
The following action(s) should be taken:
• Determine whether or not the error can be addressed from the hosT
system.
• If the error cannot be addressed from the host system, attempt to clear
the error by taking the action indicated in the table(s) which appear in this
section.
• If the prescribed action(s) do not clear the error, initiate a controlled
power-down sequence:
- Wait for all information currently held in the buffer to be transferred to
the host system.
-Turn off the Scanner transport using the side panel switch.
-Turn off the Scanner power using the main power switch.
-Wait 10 - 30 seconds.
-Turn on the Scanner power using the main power switch.
-Turn on the Scanner transport using the side panel switch.
• If the error condition is not cleared using the controlled power-down
sequence, contact service.
6 OPERATOR MESSAGES
Users
System administrators