14.
Mount the right-hand INNER SIDE PANEL to the ML2000P.
15.
Locate CONNECTOR A4x31 in the ML2000 P Harness. Plug in A4X31 from the
HUMIDIFIER. See figure 1-8.
16.
Route the HUMIDIFIER HARNESS through the CABLE DUCT and close the DUCT.
17.
Mount the parts shown in DETAIL A figure 1-10 to the fresh WATER INPUT of the
HUMIDIFIER
18.
Mount the parts shown in DETAIL B figure 1-10 to the fresh WATER INPUT of the
PROCESSOR. If there is a PLASTIC ADAPTER at the PROCESSOR WATER IN, take it
out and discard it.
To avoid leakage, carefully seal the threads of the ADAPTER (3/8 to 1/ in.),
T-ADAPTER and MANUAL VALVE with PIPE THREAD TAPE TL2190 (PN 952960)
19.
Connect the other end of the T-ADAPTER to the WATER SUPPLY.
NOTE
The PRESSURE HOSE for the WATER SUPPLY is not supplied with the HUMIDIFIER KIT.
INSTALLATION INSTRUCTIONS
HUMIDIFIER ML2000 P
II 3477-D
11/1997
1-10
KODAK AG, Stuttgart