background image

1 of 10 

The AQUATRAP

TM

 LGR Portable Dehumidifier 

 

Model AT100S Instruction Manual 

 
 

READ AND SAVE THESE INSTRUCTIONS 

 
Note:  1. Read and understand all operating instructions before using the AT100S AquaTrap       

LGR Portable Dehumidifier 

 
 

2. Save this manual for future reference. 

 
This instruction manual provides important information on the use and care of the AquaTrap 
LGR Portable Dehumidifier – Model AT100S. These instructions must be carefully followed in 
order to operate the unit safely and correctly. If there are any questions regarding the use of the 
unit, please contact Abatement Technologies immediately at 800-634-9091 U.S. or 905-871-
4720 Canada. 
 
Abatement Technologies strongly urges users of commercial dehumidification units and related 
accessories to follow the most recent guidelines and/or standards published by the 
Occupational Safety and Health Administration, Environmental Protection Agency, and all 
Federal, State, Provincial, and local regulations. 
 

COMPONENT VIEW  

 

Patent 

Pending          

801862R03

 

Summary of Contents for AQUATRAP AT100S

Page 1: ...S These instructions must be carefully followed in order to operate the unit safely and correctly If there are any questions regarding the use of the unit please contact Abatement Technologies immediately at 800 634 9091 U S or 905 871 4720 Canada Abatement Technologies strongly urges users of commercial dehumidification units and related accessories to follow the most recent guidelines and or sta...

Page 2: ...emperature and or humidity drops a point will be reached where the surface temperature of the evaporator will be below freezing and the water will accumulate as frost on the evaporator surface Periodic defrosting will be required to melt the frost and to direct the water run off to the pump As to when defrosting takes place this is automatically determined and controlled by the unit The AT100S can...

Page 3: ...at prevents simultaneous start up of multiple units after a power outage and subsequent re energization If the unit was in operation before a power outage it will be re started automatically but randomly within 10 seconds when power resumes It is recommended that a Ground Fault Current Interrupt GFCI device be used in the electrical supply circuit A GFCI is an electrical safety device that will tr...

Page 4: ...on or recovery from a thermal overload over heating condition If all covers are not in place the intended protection from the motorized impeller will not be present keep clear of the motorized impeller to reduce the risk of injury WARNING To reduce risk of fire or electrical shock do not use the AT100S with any solid state speed control device CAUTION For general dehumidification use only Do not u...

Page 5: ...Hours Indicates the number of hours that the unit has been operating since it was last reset to zero To reset Job Hours to zero depress the ENTER button Total Hours Indicates the number of hours that the unit has been operating since it was new Language Setting Each press of the ENTER button cycles through the following languages on the LCD ENGLISH SPANISH FRENCH Press MENU to confirm the choice o...

Page 6: ...n remove the entire filter As long as the unit has not been tampered with and all panels are in place the unit has been designed to allow the filter to be changed without exposing the operator to mechanical or electrical hazards The original equipment high efficiency pleated air filter is rated MERV 8 and has been specifically designed to allow the unit to remain clean internally and perform to pu...

Page 7: ...sed well With the Heat Exchanger removed full access is available to clean the fins of the aluminum evaporator and condenser coils The dirtiest surfaces to be cleaned will be on the air entering sides Vacuuming with a brush should be effective at removing the debris if not contact qualified service personnel if more aggressive cleaning is required There is also full access to clean the Drain Pan D...

Page 8: ...residual water corrosive environment or other conditions beyond the control of ATI 6 Reimbursement for warrantable replacement parts not supplied by ATI 7 Shipping damage or damage as a result of abuse in transporting the unit ATI does not warrant that the goods sold are merchantable or fit for any particular purpose ATI makes no warranties other than as stated in this paragraph All other warranti...

Page 9: ...sistance contact Abatement Technologies Customer Service Department at 800 634 9091 U S or 905 871 4720 Canada AT100S SPECIFICATIONS AHAM Rating 80o 60 RH 100 Pts Day Dimensions 19 L x 18 3 W x 38 8 H Dehumidifier Type Low Grain Refrigerant LGR Water Removal at 80o F 20 RH Yes Weight 125 Pounds Shipping Weight 145 Pounds Cabinet Material Stainless Steel Filter MERV 8 Drain Hose Length 35 Feet Cord...

Page 10: ...d be within nameplate limits Compressor windings open Contact qualified service personnel Compressor Will Not Run Seized compressor Contact qualified service personnel Shorted or incorrect wiring Contact qualified service personnel Shorted capacitor Contact qualified service personnel Compressor short cycling See Compressor Short Cycles Fuse or breaker setting too low Check nameplate fuse size Bro...