Printer Setup 1-9
ENCAD
®
T-200
TM
Reference Guide
4
The cutter fits in the printer on the left side of the carriage. To remove an old cutter,
push the cutter lever down and pull it out. Install the new cutter by pushing it into the
slot until it clicks into place.
5
Repeat steps 1-3 to move the carriage back into the service station. This ensures
that the cutter blade is in the home position.
Testing the cartridges
After the cartridges have been installed and media is loaded, run the following tests as
described in the sections which follow: color test, prime pattern, cartridge alignment,
and deadband test.
Printing the color test
Printing the color test verifies a proper manual prime and that pressure is set properly. It
prints a solid band of each of the four colors.
➪
➪
➪
➪
➪
To print the color test
1
Be sure media is loaded in the printer.
2
Choose
Utility Menu/Service Menu/Diag Menu/Color Test=100%
.
3
Press
Select
twice.
The test prints.
4
Verify that all bands print a solid pattern. This indicates that the cartridges were
properly primed. If a solid pattern is not printed, run the color test again.