Page 22 of 35
8.3.1.4
Definition of the reference conditions
Here can be defined the desired measured media reference conditions for pressure and temperature
and times for the filter and averaging.
Factory pre-setting for reference temperature and reference pressure are 20 °C, 1000 hPa
All volume flow values (m³/h) and consumption values indicated in the display are
related to 20 °C and 1000 hPa (according to ISO 1217 intake condition)
Alternatively 0 °C and 1013 hPa (=standard cubic meter) can also be entered as a reference.
Do not enter the operation pressure or the operation temperature under reference
conditions
!
Setup
Sensor Setup
Advanced
Setup
Sensor Setup
Advanced
Ref.Pref
Setup
Sensor Setup
Advanced
Ref.Temp
To make changes, first select a menu with
button
„
“
and confirm selection by pressing
„OK“
.
In order to change, e.g. the unit, first select by
pressing key
„
“
the field
“Units”
and then
key “
OK”
.
Select with the key
„
“
the correct unit and
then confirm selection by pressing 2x
„OK“
.
Input / change of the value by selecting the
respective position with button
„
“
and
entering by pressing button
„OK“
.
By pressing
„
“
the position value is
incremented by 1.
Complete with
"OK"
and
activate next number position.
Procedure for changing the reference
temperature is the same.