![Kobold KEC-1 Operating Instructions Manual Download Page 57](http://html1.mh-extra.com/html/kobold/kec-1/kec-1_operating-instructions-manual_1982459057.webp)
Installation
KEC-2 K01/1216
Page 14 of 35
6.2.1 Installation of KEC-2
The sensor KEC-2 is pre-supplied with the measuring section.
6.3
Alignment Display (Housing)
The sensor housing KEC-2 can be turned in both directions, max. 345 °. For this purpose, the
housing-connecting nut must be opened. The housing can be rotated to the desired position, a bigger
rotaion angle is prevented by internal stop pins.
After that, the housing-connecting nut is firmly retighten
6.4 T
ightening torques
To secure and guarantee of the function and tightness following tightening torques have to be
applied, see table 1.
Table 1
Pos Description
Tightening torque
[Nm]
20
KEC-2 cover with glass
3
30
KEC-2 cover without window
3
50
Grub screw with hexagon socket M4x6 DIN 914 A2
2
130 KEC-2
nut
15
150
Cylinder screw DIN 6912 - M5x10 A2-70
4