![Kobold KEC-1 Operating Instructions Manual Download Page 35](http://html1.mh-extra.com/html/kobold/kec-1/kec-1_operating-instructions-manual_1982459035.webp)
Operation
KEC-1
K01/1216
Page
35
of
43
Modbus
Register
Register
Address
No.of
Byte
Data
Type
Description
Default
Read
Write
Unit /Comment
1269 1268 4 UInt32
Consumption m³ before
comma
x R
1275 1274 4 UInt32
Consumption Nm³ before
comma
x R
1281 1280 4 UInt32
Consumption ltr before comma
x R
1287 1286 4 UInt32
Consumption Nltr before
comma
x R
1293 1292 4 UInt32
Consumption cf before comma
x R
1299 1298 4 UInt32
Consumption Ncf before
comma
x R
1305 1304 4 UInt32
Consumption kg before
comma
x R
1311 1310 4 UInt32
Consumption kWh before
comma
x R
1347 1346 4 Float
Velocity m/s
1355 1354 4 Float
Velocity Nm/s
1363 1362 4 Float
Velocity Ft/min
1371 1370 4 Float
Velocity NFt/min
1419 1418 4 Float
GasTemp °C
1427 1426 4 Float
GasTemp °F
Remark:
For more additional Modbus values please refer to
KECXX_Modbus_RTU_Slave_Installation_1.00_EN.doc