MINOR CHANGE MACHINE FAMILIARIZATION
2
Dynamic Acera 03/05 Rev. 05
Page 3-70
9. Preventive Maintenance Program – FIGURE 2.12A
MONITOR
SYSTEM
OK
256Hr
E/G
OIL
CH
AFT
123Hr
FUEL
FIL
CH
AFT
135Hr
HYD
FIL
CH
AFT
1275Hr
HYD
OIL
CH
AFT
2250RPM
Press mode
switch to increase the
number on the LCD
Note 6:
If the Mode or Buzzer Stop switch is depressed
continuously
, hours will change rapidly
Note 2:
Press the Screen Change switch
to get to the item for calibration.
Note 1:
For viewing
Note 3:
For adjusting
Note 4:
Once the item to be adjusted is shown
on the LCD press Screen Change switch
continuously for 5 to 10 seconds and release it.
Note:
If
CONTRAST 50
is displayed on the screen, press " " to cancel Contrast
adjustment mode and continue normal PM adjustment.
After setting the desired
hours, press the screen
change switch continuously
for 5 ~ 10 seconds to
calibrate the next item for
schedule maintenance (
*
).
(The system will record the
hours instantly when pressing
the Screen Change switch).
If no more items are to be
calibrated, after setting the
desired hours on the last item,
press and release the screen
change switch to record them
in the system.
Once the hours are recorded into
the system, the LCD will show the
next item accordingly. Simply scroll
through each one of the items, by
pressing the Screen Change switch
until the screen shows the time :
(
*
) Since the
Fuel Fil
ter
Ch
ange,
Hyd
raulic
Fil
ter
Ch
ange, and
Hyd
raulic
Oil Ch
ange icons keep
record of hours elapsed from
maintenance, it is best to set them
to Zero accordingly by simultaneusly
pressing the "Mode" and "Buzzer Stop"
switches.
Press the
buzzer stop
switch to decrease the
number on the LCD
256Hr
E/G
OIL
CH
AFT
123Hr
FUEL
FIL
CH
AFT
135Hr
HYD
FIL
CH
AFT
1275Hr
HYD
OIL
CH
AFT
YQ102ProgramPM
10 : 10
10 : 10
Within 5 sec.
(Automatically)
Notes: 1.
The engine oil change warning display default setting is 500 hours, but no alarm sounds.
2.
The ITCS system does not have warning display icons nor alarm sound for fuel filter,
hydraulic oil filter, and hydraulic oil.
Press the Screen Change switch to obtain the
hours elapsed since the last maintenance.
The display hours on the LCD are set to
4 digits for hydraulic oil, and 3 digits for all others.
3.
The display time on the LCD can be returned to zero by simultaneously pressing and
holding the " " selector switch and " " switch for 5 seconds.
NOTE 5: System must be in "A" or "M"
mode for calibration to take place.
If System is in "B" mode, flow setting
will display and calibration will not take
place.
Press
to record
FIGURE 2.12A