Page 3-51
Dynamic Acera 03/05 Rev. 05
OK
OK
256 Hr
E/G
OIL
ATF
CH
256 Hr
E/G
OIL
ATF
CH
OK
5.How to Calibrate the Engine Oil Change Interval.
TURN ON THE
IGNITION
SWITCH.
PRESS THE
GAUGE CLUSTER
SCREEN CHANGE
SWITCH
ONCE.
2250 RPM
PRESS THE
GAUGE CLUSTER
SCREEN CHANGE
SWITCH AGAIN,
AND THE ACCU-
MULATED
HOURS SINCE
THE LAST ENGINE
SERVICE IS
DISPLAYED.
PRESS THE GAUGE CLUSTER SCREEN
CHANGE SWITCH FOR 5 TO 10 SEC. AND
RELEASE IT.
THIS SIGNAL AP-
PEARS ON THE
SCREEN AS LONG AS
YOU DEPRESS THE
SCREEN CHANGE
SWITCH. IT WILL
CHANGE AS SOON
AS THE SWITCH IS
RELEASED
PRESS THE MODE SWITCH
TO INCREASE THE HOURS
PRESS THE BUZZER SWITCH
TO DECREASE THE HOURS
THIS SIGNAL DOES
NOT FLICKER
NOTE: IF SWITCH
IS DEPRESSED
CONTINUOUSLY,
HOURS WILL
CHANGE RAP-
IDLY
AFTER SETTING
THE DESIRED
HOURS, PRESS
THE GAUGE
CLUSTER SCREEN
CHANGE SWITCH
TO RECORD THEM
IN THE SYSTEM
MACHINE FAMILIARIZATION