Page 3-21
Dynamic Acera 03/05 Rev. 05
Step A-Max./Min. flow rate adjusting procedure
d.
Press the screen change switch for 5 ~ 10
seconds and release. See FIGURE 3.16.a
the LCD screen displays the flow rate
stored in memory.
e.
Press the mode switch once, see FIGURE
3.17.b flow rate value will increase in 10L/
min. increments. If mode switch is held
down for more than five seconds, flow rate
will increase rapidly. Release mode switch
when you have reached your desired
value.
Continued on next page -
FIGURE 3.16.a
c. Breaker mode
Pressing the work mode selector twice
from “M” mode, changes the machine to
“B” or breaker mode. Located on the
right of M mode. See FIGURE 3.16.a. The pur-
pose of this mode is to allow the operator to
quickly adjust the pump flow rates for various
attachments while sitting in the cab. When the
breaker or attachment is in operation the flow
volume is switched automatically to the opera-
tors preset pump flow. The flow returns to nor-
mal setting when the breaker or attachment is
not being used.
FIGURE 3.16.b
NOTE
The breaker flow is not set at the factory to deliver
maximum pump flow. To change the flow rate to a
higher or lower setting see the following
information. “Gauge cluster will display pump flow
in metric units only.”
1. With Safety Lock in the up or lock position,
place keyswitch to on position, do not start
engine. See FIGURE 3.16.b
2. Press the mode switch two times, the LCD
screen will display the set flow rate of the
breaker circuit. See FIGURE 3.17.c.
3. To change the pump flow (both pumps are
changed SK160 and up) move machine to
safe work area and turn keyswitch to off. Wait
ten seconds then procede.
KPSS WORK MODE LAMP
NOTE
I
t is impossible to adjust flow rate after starting of
engine.
Minimum / Max flow rate
adjusting
procedure
1. Preparation
a. Keyswitch must be in off position for ten
seconds.
b. Turn keyswitch to on position do not start
engine, place safety lock in up position.
c.
Press mode switch twice to select (B)
Breaker mode.
MACHINE FAMILIARIZATION
S C R E E N
C H A N G E
SWITCH
Do not operate this machine unless you have
read and understand the instructions in the
OPERATORS MANUAL. Improper machine
operation is dangerous and could result in
injury or death.
WARNING