No.
Parts
Parts/Normal condition
Corrective action
1
Power-supply box to Cab
harness
Make sure that connector between
power-supply box and cab harness is
connected.
Check connections.
2
Cable to Cab harness
Make sure that connector between cable
and cab harness is connected.
Check connections.
3
Cable to Camera cable
Make sure that connector between cable
and camera cable should is connected.
Check connections.
4
Fuse & Relay box
Make sure that No. 30 fuse (5A) did not
melt down.
Replace fuse.
5
Setting of camera
Make sure that CAMERA 1 SETTING in
SERVICE ADJUSTMENT1-2 screen is ON,
and CAMERA 2 and CAMERA 3
SETTING are OFF.
Check the setting.
No.
Parts
Parts/Normal condition
Corrective action
1
Setting of camera
Make sure that CAMERA 1 SETTING in
SERVICE ADJUSTMENT1-2 screen is ON,
and CAMERA 2 and CAMERA 3
SETTING are OFF.
Check the setting.
21
2)
Troubleshooting
1.
Gauge cluster is powered on but picture does not appear and it shows blue screen.
2.
Gauge cluster is powered on but picture does not appear and it shows fuel consumption graph or
logo.
[
21. MECHATRO CONTROLLER
]
21-41
Copyright © 2015 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S5YN0046E03] [0109CsCshWbYs]