23
Attaching the Media Connection to the Media Adapter
1.
Carefully plug the connector of the media connection into the media
adapter with the flat side facing the wall (or pipe).
2.
Then tighten the 2 fixing screws (PZ-3). (See also page 25.)
The
media connection
is plugged and screwed
on from below.
Media adapter
Unical 9000
8 Assembly
NOTICE
• If the media connection hose is strongly twisted, you must loosen the
connection at the basic unit and refasten it with proper orientation using
the included special wrench.
• Be sure to take account of the chemical resistance of the process-wetted
materials of the media adapter, media connection and pump.
When hot vapor or aggressive cleaning agents are to be used, an adapter
for additional media (ZU 0654, ZU 0655) is available for the retractable fit-
tings of the Ceramat Series. The SensoGate WA 130(H) provides a suitable
option (PEEK media connection with integrated connection for additional
medium).