Diaphragm pump PJ25481-950.50.18
Installation and connection
Translation of original Installation Instructions, english, KNF 125530-316634 06/18
13
6.2. Electrical connection
DANGER
Extreme danger from electrical shock
Only have the pump connected by an authorized
specialist.
Only have the pump connected when the power
supply is disconnected.
When connecting the device to a power source, the relevant
standards, directives, regulations, and technical standards
must be observed.
Connecting pump
1. Compare the supply data with the data on the motor plate. For
maximum operating current of the pump see pump’s type
plate.
The voltage must not vary by more than + 10% and – 10%
from that shown on the type plate.
2. Insert the mains cable plug into a properly installed shockproof
socket.
Ensure sufficient dimensioning of the connection cables.
6.3. Pneumatic connection
CAUTION
Personal injury or damages to property by ejected
protective plugs
If the protective plug at the pressure side of the
pump hasn’t been removed, it could be ejected be-
cause of the overpressure during operation.
Remove the protective plug during the installa-
tion.
Only connect components to the pump which are designed for
the pneumatic data of the pump (see Chapter 4, Technical
Data).
If the pump s used as a vacuum pump, safely discharge the
pump exhaust at the pump’s pneumatic outlet.
Connected
components
Pump exhaust