Technical Data
Diaphragm pump PJ25481-950.50.18
8
Translation of original Installation Instructions, english, KNF 125530-316634 06/18
4. Technical Data
Pump materials
Assembly
Material
Diaphragm
PTFE coated
Valve plates
FFPM
O-ring
FPM (head 1-3)
FFPM (head 4)
Head plate
PPS
Intermediate plate
PPS
Tab. 2
Pneumatic values
Parameter
Value
Max. permissible operating
pressure [bar g]
-
Ultimate vacuum [mbar abs.]
with closed gas ballast
2.0
Delivery rate at atm. pressure
and 5V control voltage [l/min]*
55.0
Tab. 3
*Liters in standard state (1013 mbar)
Pneumatic Connections
Pump type
Value
PJ25481-950.50.18
Hose ID 10
Tab. 4
Electrical data
Parameter
Value
Automatic voltage selection
100-240 V
50 – 60 Hz
Max. current consumption [A]
1.9
Max. power consumption [W]
140
Maximum permitted mains
voltage fluctuations
± 10%
Protection class Motor
IP 20
Protection class Pump
IP 20
Tab. 5
The pump is supplied by a universal power supply with inte-
grated overload protection.
They are protected against overheating by a temperature sen-
sor on the motor board and equipped with overcurrent protec-
tion.
If one of these safety functions is triggered, the pump will be
shut down and must be manually reset, as follows:
Separate pump from mains.
Remove the cause(s) of the fault before restarting.