Installation and connection
Diaphragm pump PJ25481-950.50.18
14
Translation of original Installation Instructions, english, KNF 125530-316634 06/18
Connecting pump
A marking on the pump head shows the direction of flow.
Confusion between suction and pressure sides can lead to
breakage of connected components on the suction and pres-
sure sides.
1. Remove the protective plugs from the hose connection
threads.
2. Connect the suction line and pressure line (see Chapter 4,
Tab. 7 for mounting dimensions).
3. Lay the suction and pressure line at a downward angle to pre-
vent condensate from running into the pump.