When connecting the appliance to the system, you should provide a zone that is always open (such as
bathroom area) to enable the excess heat dissipation of the water in the body of the boiler.
The maximum mains water pressure should never exceed 2.5 bar; recommended operating pressure is 1.5 bar
(with the appliance in operation).
In the event of water with hardness exceeding 28 °f, an anti-limescale device must be installed. This must be
selected on the basis of the specific properties of the water.
TO AVOID COMPROMISING THE OPERATION AND LIFE OF THE HEAT PUMP, INSTALLATION OF A FILTER
AND A MAGNETIC DIRT SEPARATOR IS RECOMMENDED DOWNSTREAM OF THE RETURN PIPE ON THE
APPLIANCE.
The appliance must be mounted exclusively by qualified personnel. Scrupulously comply with the instructions given
in this guide.
The manufacturer declines any liability for damages caused due to incorrect assembly.
THE DISPLAY
The appliance's operating mode is displayed on the console. After turning on the menu, it is possible to choose from
many types of display and available settings according to the selected menu.
The figures below show the display when the appliance is in ON mode.
Set
1
2
3
6
5
4
Set
1
2
3
6
5
4
DIALOGUE
REAL WORK POWER
(It is shown flashing only when it is different
from the one actually set)
17:19
t.H2O
60°
C
WORK 3
2
CLOCK
TEMPERATURE REFERENCE
t.H2O = water temperature in boiler
t.BoL = boiler DHW storage tank
temperature
t.PUF = centralised buffer temperature
t.AMb = room temperature
TEMPERATURE
2nd LED SERIES
1st LED SERIES