PELLET-BURNING BOILER ECOMPACT 150-190-250-290
EN -
Rev 1.1
18
Height and draught: In order for the appliance to perform satisfactorily the chimney height must be sufficient to ensure a
draught of 12 Pa so as to clear the products of combustion and prevent smoke problems into the room.
A chimney height of not less than 4.5 m measured vertically from the outlet of the stove to the top of the chimney
should be satisfactory. Alternatively the calculation procedure given in BS EN 13384-1:2002 may be used as the basis
for deciding whether a particular chimney design will provide sufficient draught.
The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building
Regulations Approved Document J diagram 17 or 18. Please see the diagram below.