WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP
33
EN - Rev. 1.2
Cleaning the flue
The flue must be cleaned at least once a year, at the beginning of winter, and whenever it becomes necessary.
It is important to check for any obstructions in the flue before switching the appliance on following long periods of
inactivity.
If the flue is not cleaned, the operation of the appliance and its components may be compromised.
The frequency for cleaning the appliance and flue depends on the quality of wood used.
USE TOP QUALITY WOOD TO OBTAIN THE BEST RESULTS.
Maintenance
Timely and systematic maintenance is essential for guaranteeing correct operation, optimal heat performance and
durability of the device. Therefore, qualified staff should check the appliance at least once a year at the beginning of the
season.
You must periodically check the seals because the latter guarantee the air- and water-tightness of the appliance and its
good functioning; if they are worn or damaged you need to be replace them immediately by contacting a
Klover
Authorised technical assistance centre.
For proper operation, the appliance must undergo routine maintenance performed by a Klover
Authorised
technical assistance centre
at least once a year.
Maintenance of the boiler unit
The appliance is supplied with a special additive call LONG LIFE, designed to protect the boiler unit
and heat exchangers from rust and to keep the water inside the boiler unit clean. LONG LIFE
should be diluted to 2% with water inside the boiler unit. It can be poured directly into the boiler unit
before or after filling it with water.
For ease of use, a table is provided of the annual dilution dosages of LONG LIFE:
It is recommended to empty the boiler unit water every 2 years and remove any solid residues caked on the
bottom. These residues reduce the effectiveness of LONG LIFE. The boiler unit should then be refilled and the
optimum dosage of LONG LIFE should be added. If too much LONG LIFE is added by accident, empty and refill
the boiler unit. Observance of the proper frequency for cleaning the boiler unit will prolong its life and is
essential for the validity of the warranty.
ATTENTION!!! NON-USE AND OR AN INCORRECT DOSAGE OF LONG LIFE WILL INVALIDATE THE WARRANTY
ON THE BOILER UNIT.
LONG LIFE gas been designed and tested on SICURO TOP products; KLOVER declines all liability arising from the use
of LONG LIFE in products or applications other than those indicated.
Boiler unit
water
capacity
Recommended
dose of LONG LIFE
(2%)
Recommended
dose of LONG
LIFE (1%) after the
first year
Recommended
dose of LONG LIFE (2%) after
the first year
50 l
1000 ml
500 ml
Empty and clean the entire
boiler unit. Next restore the
level of water content, adding
1000 ml of LONG LIFE.