WOOD BURNING BOILER COOKER ALTEA 110 SICURO TOP
29
EN - Rev. 1.2
CLEANING AND MAINTENANCE
Precautions before cleaning
Before carrying out any cleaning or maintenance operations, make sure that:
-
the appliance is off and has cooled down completely.
-
the ash is completely cold.
-
the ash vacuum device used for cleaning is suitable and its filter is in good condition.
Before re-starting the appliance, re-install all previously removed components.
During cleaning operations, use the personal protection devices specified in Directive 89/391/EEC.
The required cleaning frequency depends on the type and quality of the pellets used. The schedule indicated below may
therefore vary.
Any problem affecting the appliance caused by lack of cleaning will not be covered by the warranty. The failure
of these operations could affect the safety of the product.
Cleaning the combustion chamber
It is important to clean the combustion chamber at least once a month to ensure the proper and an optimum
performance and operation of the appliance. Please proceed as follows:
Using a small brush, remove any residue which has formed on the internal walls of the combustion chamber. Do not use
tools that can reduce the thickness of the metal sheet of the boiler unit.
Remove the pipes connecting the appliance to the flue and clean them if necessary.
After removing the upper damper, remove the cooking rings and hotplate
(figures 1 and 2)
.
1
2